1
EN
INSTALLATION, USE AND MAINTENANCE MANUAL
To reverse the outlet connector, proceed as follows:
1. Unscrew the screws and remove the two side covers (with and without expulsion).
2. Unscrew the screws and remove the rear cover, shield and front cover.
. Disconnect the motor power supply cable from the power supply board.
. Unscrew the screws and remove the top section.
. Unscrew the screws and remove the reversible silencer.
. Rotate the silencer through 180° replace it inside the top section. Ensure that the O-rings of the central
section are correctly positioned and that there are no disconnected cables.
7. Replace the top section on the main vacuum unit.
8. Replace the rear cover, front cover, shield and side covers (with and without expulsion).
ATTENTION: Before carrying out this operation, it is compulsory to
unplug the unit from the 230 V power supply wall socket.
TOP SECTION
SIDE COVER
SHIELD
AND FRONT COVER
SILENCER
REAR COVER
180°