56041481
SUMMARY OF MAINTENANCE
CONTROLS (battery version)
Warning
: the following interventions must be done
with machine in Off condition and master
key out. All the periodic maintenance
operations must be performed by skilled
personnel or by an authorized service centre.
Note
: the battery life will depend on a good periodic
maintenance (check of the level of the
electrolyte and of battery voltage). Besides it
must be taken into account that an unused
battery is submitted to a self-discharge
phenomenon. In the event that the machine is
not used for a long time (e.g. 3 or 4 weeks) it is
necessary TO RECHARGE THE BATTERY; infact
the battery voltage MUST NEVER drop down
below 20 Volt.
25
CONTROL
UPON
DELIVERY
EVERY
30
HOURS
EVERY
50
HOURS
EVERY
100
HOURS
EVERY
400
HOURS
Battery liquid level and
voltage
check
•
•
OR EVERY TWO WEEKS
Check the carbon brushes of
all electrical motors and
replace them if worn
•
Belt tension
•
•
Brake adjustment
•
•
Filter shaker
•
Nut and screw tightness
•
Wear of main brush and side
brushes
•
Panel filter cleaning
•
Sealing of gaskets of filter
compartment and of flaps
•
•
GREASE
:
chain of the steering crown
•