26
SH SOLAR E, D
Original Instructions
7 Trouble
Shooting
You have chosen the best quality and therefore deserve the best service. All machines feature an “Er-
ror detection system” that will stop the machine in case of a severe error that needs immediate atten-
tion. The red light of the STOP button will fl ash, and the display in the inspection window will indicate
the nature of the error. Please refer to the specifi c section (7.2 to 7.3) that represents your machine.
Though the user can correct some of these errors, you should note the error and contact the nearest
Nilfi sk service organisation. To avoid unnecessary dis ap point ments, you should check section "
7.1
General trouble shooting
" before contacting the nearest Nilfi sk service organisation.
Should other malfunctions occur than those mentioned in sections 7.1 to 7.3, please contact your
nearest Nilfi sk service organisation.
7.1 General trouble shooting - all models
Symptom
Reason
Action
Machine will not start
> A fuse has blown
• Change the fuse.
(NO ERROR indication)
> Power disconnected
• Connect power.
Fuses blow
> Installation does not
• Change to an installation.
correspond to the ampere
corresponding to the ampere
consumption of the machine
consumption of the machine
at
a
minimum.
Change
the
fuse.
Working pressure too low
> Nozzle worn
• Replace the nozzle.
> Wrong spray lance
• Replace the spray lance
(see
section
4.1.4).
> Reduction valve of spray
• Turn reduction valve com-
lance not adjusted to max.
pletely counter-clockwise
pressure.
(see
section
4.1.4).
> Nozzle partly clogged up
• Clean the nozzle
(see
section
6.4).
Working pressure fl uctuating
> Insuffi cient water supply
• Dismount the cabinet and
check that the water tank is
not drained of water during
operation of the machine. If it
is, clean the water inlet fi lter
of the machine. If that does
not solve the problem, the
water supply for the machine
is
insuffi
cient.
NB!
Avoid long, thin hoses
(min.
3/4").
> High pressure hoses too long
• Dismount high pressure
extension hoses and retry.
Extension hose max. 50 m.
NB!
Avoid long extension