15
SH SOLAR E, D
Original Instructions
4.1.6 Application of deter-
gents (internal)
If your machine is equipped
with an
optional
, internally
mounted chemical system –
dosing the chemical to the inlet
of the high pressure pump,
please refer to the separate
“Operating instructions, Chemi-
cal dosing” on this option.
4.2 Operation
4.2.1 Starting up
ON
The shut-off cock on the water
inlet should be open, and the
spray handle on the high pres-
sure hose should be closed.
1. Turn the main switch (2) to
position -
ON
-.
2. Push the green "
START
"
push button (3).
Check on the pressure gauge
(6) that a pressure is being
built up in the system and that
the motor of the machine stops
within appr. 20 seconds with
the green “START” push button
(3) lit. The machine is now in
“Stand-by” mode waiting for the
operator to activate the spray
handle.
If a pressure is not being built
up, vent the machine as de-
scribed in sections
3.7 - 3.8
Venting
.
If the motor of the Does not
start or stops unintendedly
with the red “STOP” push but-
ton (4) fl ashing, an error is
present. Read the error mes-
sage through the "Inspection
window" and refer to section "
7
Troubleshooting
".
2
3
4
6
10