ELECTRICAL SYSTEM
ENGLISH
SERVICE MANUAL
40
9097091000(1)2007-06
Micromatic
TM
M17B - Micromatic
TM
M17E
FUSE CHECK/REPLACEMENT [MICROMATIC M17B]
Check that the switches (5 and 6) are turned to “0”.
Remove the recovery water tank and disconnect the battery negative terminal (50) according to the following procedure:
If there is recovery water in the tank (43), drain it through the hose (22).
Disconnect the vacuum hose (29) from the squeegee (17).
Open the cover (12).
Grasp the recovery water tank (A) in the area (B) and lift it, as shown in the figure, then disconnect the vacuum hose (C)
from the tank and remove the tank (A) together with the hoses (D) and (E).
Remove the screws (F) and carefully pull out the electrical component box cover (G).
Check/replace the fuses:
Brush fuse (H): 40 A
Vacuum system fuse (I): 30 A
Solenoid valve and electronic board fuse (J): 5 A
Assemble in the reverse order of disassembly.