9 Trouble-shooting

Please ensure that you check the following before contacting the Nilfisk service organization:

Symptom 

Cause 

Recommended action

Machine refuses to start

  Machine not plugged in 

Plug in machine.

 

Defective socket 

Try another socket.

 

Fuse has blown 

Replace fuse. Switch off other machines.

 

Defective extension cable  Try without the extension cable.

Fluctuating pressure 

Pump sucking air 

Check that hoses and connections are air- 

   tight.

 

Valves dirty, worn out  

Clean and replace or refer to local Nilfisk-  

 

or stuck 

distributor.

 

Pump seals worn out 

Clean and replace or refer to local Nilfisk-  

   distributor.

Motor busses

 

Low voltage or  

Activate the trigger of the spray handle.

 

low temperature

Machine stops

 

Fuse has blown  

Replace fuse. Switch off other machines. 

 

Incorrect mains voltage 

Check that the mains voltage corresponds  

 

 

to specification on the model tag.

 

Thermal sensor activated 

Leave the washer for 5 minutes to cool   

   down.

 

Nozzle partially blocked 

Clean the nozzle (see section 7.2).

Fuse blows

 

Fuse too small 

Change to an installation higher than the  

 

 

amp. consumption of the machine. 

 

 

You may try without the extension cable.

Machine pulsating

 

Air in inlet hose/pump 

Allow machine to run with open trigger until  

 

 

regular working pressure resumes.

 

Inadequate supply of  

Check that the water supply corresponds to 

 

mains water 

specifications required (see model tag).

  

NB!

 Avoid using long, thin hoses (min. 1/2").

 

Nozzle partially blocked 

Clean the nozzle (see section 7.2).

 

Water filter blocked 

Clean the filter (see section 7.1).

 

Hose kinked 

Straighten out hose.

Machine often starts 

 

Contact your nearest Nilfisk Service 

and stops by itself 

 Centre.

 

Spray handle is leaking 

Replace seat/ball/O-ring in the valve of the  

 

 

spray handle.

Machine starts, but 

 

Pump/hoses or accessory  Wait for pump/hoses or accessory to thaw.

no water comes out 

 frozen

 

No water supply  

Connect inlet water.

 

Water filter blocked 

Clean the filter (see section 7.1).

 

Nozzle blocked 

Clean the nozzle (see section 7.2).

Pump pressure drops

 

Button for regulation of  

Adjust the button to correct working pres-

 

pressure / water volume not  sure.

 

correctly adjusted

In case problems other than the above occur, please contact your local Nilfisk distributor.

Summary of Contents for MC 2C Series

Page 1: ...128337037 EN MC 2C Instruction manual...

Page 2: ...2 5 5 Start and stop of the machine when connected to a water supply 13 5 6 Start the machine when connected to open containers suction mode 13 5 7 Pressure regulation 13 5 8 Operation with detergents...

Page 3: ...able use a device in order to avoid or re duce aerosols production e g a shield covering the nozzle For protection against aerosols use a respira tory mask of class FFP 2 or higher The high water pres...

Page 4: ...or lack of experience and knowledge If the machine is used by people with re duced physical sensory or mental capabilities or lack of experience and knowledge they shall have been given supervision o...

Page 5: ...of the machine Before starting the work Inspecting the machine Do not use the machine if a supply cord or important parts of the machine are damaged e g safety de vice high pressure hose and spray han...

Page 6: ...by an authorized Nilfisk distributor or similar qualified person in order to avoid a hazard Connecting the high pressure washer to a supply system the max allowed impedance is 0 4023 Zmax Consult with...

Page 7: ...nner or acetone These sub stances damage the materials used in the machine Their spray is highly combustible explosive and poi sonous Never direct the water jet at yourself other persons not even to c...

Page 8: ...nce not described in the instructions If the machine refuses to start stops pulsates pres sure fluctuates motor busses fuse blows or no wa ter comes out check the trouble shooting diagram in these ins...

Page 9: ...1 Application 3 2 Operation elements and model survey See illustration at the end of this manual 1 Start stop switch 2 Water inlet with filter 3 High pressure connection only machines without hose ree...

Page 10: ...e hook only models without hose reel Mount the hose hook 13 on the handle 2 screws Note The hose hook can be mounted on the front as well as on the back Front position is to be used if the product is...

Page 11: ...Caution Failure to fit the filter will invalidate the guarantee 4 5 Mounting of high pressure hose Attach the high pressure hose 4 to the spray handle 7 5 Operating your pressure washer 5 1 Connection...

Page 12: ...et water i e from your own well an addi tional filter should be mounted 1 Let the water run through the water hose before con necting it to the machine to prevent sand and dirt from penetrating the ma...

Page 13: ...switch 1 to position I 5 Activate the trigger of the spray handle Always adjust the distance and thus the pressure of the nozzle to the surface which is to be cleaned Do not cover the machine during...

Page 14: ...detergent and flush with pure water or use a brush T and XT models 4 in 1 spray lance The pressure can be regulated on the 4 in 1 spray lance 6 5 2 0 2 0 6 5 2 0 6 5 Low Pressure detergent Tornado hi...

Page 15: ...al product is in direct contact with the dirt Detergents are applied from bottom to top for example on a car bodywork in order to avoid super clean areas where the detergent collects in higher concent...

Page 16: ...d activate the trigger Let the machine run until no more water runs through the spray handle 3 Stop the machine and un plug Wind the electric cable round the hooks placed on the side of the machine 4...

Page 17: ...it Check that it is intact before re mounting it The inlet filter must always be fitted inside the water inlet pipe to filter out various impurities as they will damage the pump valves CAUTION Failur...

Page 18: ...on 7 2 Fuse blows Fuse too small Change to an installation higher than the amp consumption of the machine You may try without the extension cable Machine pulsating Air in inlet hose pump Allow machine...

Page 19: ...2 gallon 8 7 8 2 8 7 7 8 8 7 7 8 10 2 9 0 10 2 9 0 10 8 9 5 10 8 9 5 10 8 9 5 Voltage phase frequency current V Hz A 115 1 60 15 115 127 1 60 15 230 1 50 10 230 1 50 10 230 1 50 12 6 230 1 50 12 6 23...

Page 20: ...ollowing standards EN 60335 1 2012 A11 2014 A13 2017 A1 2019 A14 2019 A2 2019 EN 60335 2 79 2012 EN 55014 1 2017 A11 2020 EN 55014 2 2015 EN 61000 3 2 2019 EN 61000 3 11 2019 EN 63000 2018 Following U...

Page 21: ...2019 EN 60335 2 79 2012 EN 55014 1 2017 A11 2020 EN 55014 2 2015 EN 61000 3 2 2019 EN 61000 3 11 2019 EN 63000 2018 Following the provisions of Supply of Machinery Safety Regulations 2008 1597 Electr...

Page 22: ...9 8 7a 7 4 12 11 15 13 16 1 3 2 5 17 14 10 6...

Page 23: ...77 414021 Website www nilfisk it JAPAN Nilfisk Inc 1 6 6 Kita shinyokohama Kouhoku ku Yokohama 223 0059 Tel 81 45548 2571 Website www nilfisk com MALAYSIA Nilfisk Sdn Bhd Sd 33 Jalan KIP 10 Taman Peri...

Reviews: