Scrub System, Cylindrical
80
Service Manual – Condor
™
EcoFlex
™
, BR 1100/1300 EcoFlex
™
5 Rotate the 1” wide
Idler Arm
with an adjustable wrench
so the
Idler Arm
is centered
between the two holes drilled
into the motor mount plate
This will provide a good
preliminary tension setting
6 Tighten the
Flat Head Screw
7 Remove the adjustable wrench
from the
Idler Arm
and tighten
the
Hex Screw
(shown in the
figure on the preceding page).
8
Check for 1/8” deflection at
the belt midpoint and make
any additional belt tension
adjustments as necessary
This will ensure the correct
belt performance and belt/
bearing life
9 Reinstall the
Belt Guard
and
Side Skirt Assembly
, then test
the scrub system for correct
operation
Lift Actuator Adjustment
This section explains the steps for adjusting the actuator drive nut (
Spring Housing Assembly
) setting for the
scrub deck actuator motor.
Using the Actuator Power Cord Adapter
The adjacent drawing shows the special
actuator power cord adapter (p/n 56407502)
that is needed to connect the machine’s
battery pack and actuator motor for setting
the actuator drive nut limit settings To
connect the actuator power cord adapter:
1 Open the machine battery compartment
and disconnect the battery connector The
battery pack is needed to power the scrub
deck actuator motor to correctly set the
IN
and
OUT
limit switches
2 Connect the actuator motor to be tested to
the power cord adapter end
3
Connect the alligator clips from the cord adapter (red clip to the positive and black to negative) to
battery connector or battery posts. Use the rocker switch on the actuator power cord adapter to change
the motor rotation when setting the correct actuator drive nut dimensions
Idler
Arm
Flat Head
Screw