FORM NO. 56043093 / Captor
™
4300, 4800, 5400 -
97
Designation
Pin ID
Wire ID/Color
Description
Signal Characteristic
Nominal Value
Reference To:
Range
Comments
Control Box Assembly
Output
J1-24
GRN
Shaker relay (K3)
DC Voltage
-14V
B+
12-12.6V w/o engine running 13.5-14.5V w/engine running
Shaker on
J1-25
Empty
Output
J1-26
GRA/BLU
Throttle output
DC Voltage
+14V
B- (Ground)
13.5-14.5V w/engine running
On when high engine speed is selected
J1-27
Empty
J1-28
Empty
Input
J1-29
BLK
B-
DC Voltage
-14V
B+
12-12.6V w/o engine running 13.5-14.5V w/engine running
Input
J1-30
BLK
B-
DC Voltage
-14V
B+
12-12.6V w/o engine running 13.5-14.5V w/engine running
Input
J1-31
BLK
B-
DC Voltage
-14V
B+
12-12.6V w/o engine running 13.5-14.5V w/engine running
Input
J1-32
BLK
B-
DC Voltage
-14V
B+
12-12.6V w/o engine running 13.5-14.5V w/engine running
Input
J1-33
BLK
B-
DC Voltage
-14V
B+
12-12.6V w/o engine running 13.5-14.5V w/engine running
Input
J1-34
VIO
Accessory power
DC Voltage
+14V
B- (Ground)
12-12.6V w/o engine running 13.5-14.5V w/engine running
Output
J1-35
BLU/BRN
Side broom actuator (M4) lower
DC Voltage
+14V
B- (Ground)
13.5-14.5V w/engine running
Measure between J1-35 and J1-12 when lowering side brooms
J2-1
Empty
Output
J2-2
YEL/GRA
Drive pedal sensor (R2) low side
DC Voltage
-5V
J2-17
Input
J2-3
GRA
Low LPG pressure switch (S3)
DC Voltage
-12V
B+
12-12.6V w/o engine running
On when LPG tank is empty or fuel line is disconnected
Input
J2-4
YEL/VIO
Hopper fire switch (S7)
DC Voltage
-14V
B+
13.5-14.5V w/engine running
On when internal temperature of hopper is too high
Input
J2-5
YEL/WHT
Hydraulic filter switch (S6)
DC Voltage
-14V
B+
13.5-14.5V w/engine running
On when filter is too dirty or plugged
Input
J2-6
WHT/GRA
Dust control filter switch (S5)
DC Voltage
-14V
B+
13.5-14.5V w/engine running
On when hopper filter is too dirty or
plugged
Input
J2-7
VIO/YEL
Solution empty switch (S9)
DC Voltage
-14V
B+
12-12.6V w/o engine running 13.5-14.5V w/engine running
On when solution tank is empty
Input
J2-8
GRA/YEL
Recovery full switch (S8)
DC Voltage
-14V
B+
12-12.6V w/o engine running 13.5-14.5V w/engine running
Off when recovery tank is full or disconnected
J2-9
Empty
Input
J2-10
ORN/GRA
Drive pedal sensor (R2) wiper
DC Voltage
0 to +5V
J2-2
0-5V
Input/Output
J2-11
BRN/BLU
To switch/display panel (A4)
Serial clock signal
0 to +5V
B- (Ground)
0-5V
Input/Output
J2-12
GRN/BLU
To switch/display panel (A4)
Serial data signal
0 to +5V
B- (Ground)
0-5V
Input
J2-13
BLU/BLK
Check engine light
DC Voltage
-12V
B+
12-12.6V w/o engine running
Key switch on and engine not running.
Input
J2-14
RED/BLK
Hopper interlock switch (S12)
DC Voltage
-14V
B+
12-12.6V w/o engine running 13.5-14.5V w/engine running
On when hopper is down
Input
J2-15
ORN/BLK
Main broom switch (S16)
DC Voltage
-14V
B+
12-12.6V w/o engine running 13.5-14.5V w/engine running
Off when main broom is down
Input
J2-16
BLK/YEL
Wand switch (S2)
DC Voltage
-14V
B+
12-12.6V w/o engine running 13.5-14.5V w/engine running
On with wand switch
revised 7/08
Summary of Contents for Captor 4300
Page 13: ...FORM NO 56043093 Captor 4300 4800 5400 11 THIS PAGE IS INTENTIONALLY BLANK ...
Page 68: ...66 FORM NO 56043093 Captor 4300 4800 5400 ENGINE SYSTEM FIGURE 4 TIER II revised 7 08 ...
Page 74: ...72 FORM NO 56043093 Captor 4300 4800 5400 HYDRUALIC SYSTEM ...