FORM NO. 56043093 / Captor
™
4300, 4800, 5400 -
25
TROUBLESHOOTING GUIDE
Possible Symptom
1
Hydraulic motor(s) will not stop running.
Note 1: Do all testing with the key switch ON and all machine functions OFF.
Note 2: If optional “Vacuum Wand Kit” is installed and its switch is activated the vacuum motor will turn on when the engine is started.
Hydraulic motor(s) will
not stop running.
Is the indicator light OFF at
the A2 display panel for the
malfunctioning motor?
Replace the
A2 touch pad.
Locate the malfunctioning
motors hydraulic cartridge
valve, clean or replace.
See hydraulic system’s
troubleshooting section for
locations.
Yes
No
Is the green indicator light
for the malfunctioning
motor OFF at A1 control
board?
Replace the
A1 control board.
No
Yes