![Nilfisk-Advance Captor 4300 Quick Start Troubleshooting Manual Download Page 56](http://html.mh-extra.com/html/nilfisk-advance/captor-4300/captor-4300_quick-start-troubleshooting-manual_1692992056.webp)
54
- FORM NO. 56043093 / Captor
™
4300, 4800, 5400
RECOVERY SYSTEM
TROUBLESHOOTING GUIDE
Possible Symptom
1
Vacuum motor will not operate
Part A1: Electrical
Note: Do all testing with the key switch ON, recovery tank empty and the hopper closed. Squeegee switch must be activated on the display
panel and the foot pedal moved into forward or reverse.
Vacuum motor
will not operate
Press the squeegee switch, is
its green A2 indicator light on?
On the A2 board is the
recovery tank full light on?
Locate the indicator switch
plug and jump out the
machine harness wires
GRY/YEL and BLK.
Does the light go off?
Repair machine harness
wires to A1 board
(GRN/YEL & BLK)
Does the light go off?
Press the squeegee button
along with moving the foot
pedal. On the A1 board, is the
(S8) vacuum relay light on?
Yes
Yes
No
No
No
Replace the recovery
tank full switch.
Does vacuum operate?
Yes
Replace A1 control
board does the vacuum
motor operate?
Continued on next page
Yes
No
No
No
No
Sub. a new A2 display panel
Does vacuum operate?
No
No
Summary of Contents for Captor 4300
Page 13: ...FORM NO 56043093 Captor 4300 4800 5400 11 THIS PAGE IS INTENTIONALLY BLANK ...
Page 68: ...66 FORM NO 56043093 Captor 4300 4800 5400 ENGINE SYSTEM FIGURE 4 TIER II revised 7 08 ...
Page 74: ...72 FORM NO 56043093 Captor 4300 4800 5400 HYDRUALIC SYSTEM ...
Page 75: ...FORM NO 56043093 Captor 4300 4800 5400 73 HYDRAULIC SYSTEM ...
Page 88: ...86 FORM NO 56043093 Captor 4300 4800 5400 ELECTRICAL SYSTEM THIS PAGE IS INTENTIONALLY BLANK ...
Page 102: ...100 FORM NO 56043093 Captor 4300 4800 5400 AXP EDS SYSTEM revised 12 08 ...
Page 107: ......
Page 108: ......