14
14
D
Troubleshooting
Check:
-
Mains voltage present?
-
Power cord plugged into wall socket?
-
Switch set to “AUTO/TOOL” ?
-
Load with > 60W plugged into socket?
Motor not working with switch set to ”AUTO/TOOL”
Yes
No
Connect switch
-
PCB
-
motor.
Is motor running?
Connect motor directly to
mains. Is motor working?
Replace motor.
Connect motor directly to
switch. Is motor running?
Yes
Yes
Yes
No
No
No
Check connections and
replace switch if needed.
Check connections and
replace PCB if needed.
Disconnect socket.
Reconnect socket. Plug
adequate load into socket.
Start load. Is motor running?
No
Check connections, socket and
PCB and replace if needed.
Yes
Check if machine is working
correctly. Calibrate flow sen-
sor if needed (section E.8).
Job done!!
Summary of Contents for ATTIX 33-01 IC
Page 5: ...5 5 B Technical data ATTIX 33 44Standard and L class machines...
Page 6: ...6 6 B Technical data ATTIX 33 44 M H class machines...
Page 7: ...7 7 B Technical data VHS 40 42 Standard and L class machines...
Page 8: ...8 8 B Technical data VHS 40 42 M H class machines...
Page 28: ...28 28 F Spare parts Cabinet and controlpanel...
Page 29: ...29 29 F Spare parts Motor unit floater reed sensor flow sensor buz zer PCBA and hinge snaps...
Page 30: ...30 30 F Spare parts Baseplate...
Page 31: ...31 31 F Spare parts Filter cleaning system PC Filter cleaning system IC...