E.8
Flow sensor calibration
Switch off the machine, disconnect the
mains plug and take off handle and top cover
as described in previous Section E.0.
Connect the calibration switch tool (P/N:
107416579) to connector (A) on the PCBA
(fig.1).
Position the hose diameter selector to posi-
tion “Ø32” (fig.2).
Insert the air restrictor with manometer (P/N:
62480 + P/N 40434) into the container inlet
(fig.3).
Flow sensor calibration should be carried out, if the PBCA or flow sensor has been changed
during service. Also it is recommended to do a flow sensor calibration, if the motor unit has
been replaced.
When?
1
2
3
foto