E.7
Change solenoid
1
2
3
4
Disassemble the handle and top cover as described in
previous Section E.0.
Unscrew the two plastic covers on the hatch back (fig.1).
Unscrew the valve/piston cover (fig.2).
Disconnect the solenoid wires from PCBA and earth clip.
Relieve the solenoid and unscrew the cable relief (fig.3).
Carefully take out the piston and the solenoid (fig.4)
Replace the solenoid (including wiring) and make sure it
is correct assembled and placed into correct position.
Repeat the process backwards to assemble the machine.
If needed the complete hatch back can be replaced. Unscrew the two plastic covers on
the hatch back (fig.1) and reuse the covers.
WARNING
: The
upper section of
the machine con-
tains live compo-
nents. Contact
with live compo-
nents leads to se-
rious or even fatal
injuries.
Always disconnect
mains plug before
disassembly.