26
- FORM NO. 56043115 - 34 RST
Control Panel
Scrub Deck Pressure, Solution Flow Rate, and Chemical Flow Rate Adjustments
Each of the scrub settings (Regular, Heavy, and Extreme) affects the scrub deck pressure, solution flow rate, and
chemical flow rate (if equipped). These settings are adjustable. The default values are shown in the tables below.
The scrub pressures are determined by examining the amperage through the brush motors.
Scrub Pressure & Amperage Specifications Chart
Scrub Mode
Default Pressure
Indicator
Brush Motor
Amperage
Regular Scrub
1 bar(#1)
16 AMPS
Heavy Scrub
2 bars(#2)
24 AMPS
Extreme Scrub
3 bars(#3)
38 AMPS
Default Solution Flow Rate Chart
Chemical Chart
Solution Flow Indicator
Flow Rate
0
Normal chemical setting
One bar gauge(#1)
0.3 g/m
-
10% less than normal chemical setting
Two bar gauge(#2)
0.6 g/m
+
10% more than normal chemical setting
Three bar gauge(#3)
0.9 g/m
Restoring the Scrub Pressures to Factory Default Settings
Use this procedure to restore all of the scrub deck pressure settings to their factory default values.
1. Turn the key switch to the off position.
2. While holding the Scrub On switch
(I)
depressed, turn the key switch to the on
position.
3. Continue to hold the Scrub On switch until the Scrub Off indicator
(H1)
turns
green, then release the Scrub On switch.
◦ On EcoFlex models, the display will show the pressure icon on the right top
corner indicating you are in pressure restoring mode and the factory default pressures have been restored.
Then the display will show key switch icon asking you to reset the machine.
◦ On standard models, the display will show ”d” to indicate that the factory default scrub pressures have
been restored.
4. Turn the key switch to the off position.
H1
H
I