Troubleshooting/Repair
If your Nikon Laser Rangefinder should require repair, please contact your local dealer or the store where you
purchased it. Before doing so, you are advised to consult the Troubleshooting/Repair Table below.
Symptom
Check Points
Unit does not turn on
(LCD fails to illuminate)
●
Depress POWER ON/Measurement button. (near side, top of the body)
●
Check the battery insertion
●
Replace the battery with a new one.
Unable to measure the distance
●
Be sure that nothing, such as your finger or a strap, is blocking the laser
emission aperture and laser detector aperture on the objective lens
side.
●
Be sure that the laser emission aperture and laser detector aperture on
the objective lens side are clean. Clean them if necessary.
●
Be sure that the target shape and condition are appropriate to reflect
the laser beam.
●
Replace the battery with a new one.
[- - -] (“Cannot measure”) appears
●
Be sure to hold the unit steady while measuring.
●
Be sure the target is within measurement range.
Closer target, located inside the
measurement range, cannot be
measured
●
Be sure that nothing, such as leaves or grass, is between the Nikon Laser
Rangefinder and the target.
Target beyond a certain distance
cannot be measured
●
Be sure that nothing, such as leaves or grass, is between the Nikon Laser
Rangefinder and the target.
Measurement result is unstable
●
Replace the battery with a new one.
●
Be sure that the target shape and condition are appropriate to reflect
the laser beam.
●
Be sure to hold the unit steady while measuring.
●
Be sure that nothing, such as leaves or grass, is between the Nikon Laser
Rangefinder and the target.