2.1 Device description
This confocal scanning laser ophthalmoscope is a widefield digital imaging device capable of capturing the area
from the central pole to the far periphery of the retina. The retinal images are captured in an automated, patient
friendly way without scleral depression or contact with the cornea.
The P200TE Ophthalmoscope provides widefield Scanning Laser Ophthalmoscope (SLO) fundus imaging and
Optical Coherence Tomography (OCT) imaging in one device.
Widefield Confocal Scanning Laser Ophthalmoscope (SLO) fundus imaging is achieved using red and green
lasers. These laser wavelengths penetrate the retinal structures to different depths. Each wavelength provides
information for interpretation and diagnosis.
In autofluorescence mode, the device captures
opto
map
af
images using the green laser to illuminate the eye.
This allows an image of the natural fluorescence of the eye to be captured. Fluorescent dye is not introduced
into the patient when performing autofluorescence imaging.
OCT imaging is achieved using an infrared broadband Super Luminescent Diode (SLD) source. Spectral
Domain processing techniques are applied to construct axial and cross sectional scans.
Optos’ technology is designed to operate through a minimum pupil diameter of 2 mm. Although pupil dilation is
NOT
required, the decision to dilate is a medical decision to be made by the eyecare professional.
Images are captured on the scan head and then viewed, magnified and separated into their components in the
review software.
Note
Depending on the features available on your device, you may have a subset of the features described in this
user guide.
2.2 Intended use
The P200TE is a non-contact scanning laser ophthalmoscope and optical coherence tomographer intended for
in vivo viewing and digital imaging of posterior ocular structures, including the retina, retinal nerve fiber layer,
and optic disc. It is indicated for producing high-resolution, widefield, en face reflectance images,
autofluorescence images, and axial, cross-sectional images of the posterior ocular structures.
2.3 Intended users
The device is intended for professional use only. Users
MUST
have knowledge of basic eye anatomy and
experience in operating ophthalmic imaging and diagnostic devices.
Part Number: G108707/8GSE
Page 21 of 76
Copyright 2018, Optos plc. All rights reserved.
English
Summary of Contents for Optos Monaco P200TE
Page 4: ...Page 4 of 76 Part Number G108707 8GSE English Copyright 2018 Optos plc All rights reserved ...
Page 10: ...Page 10 of 76 Part Number G108707 8GSE English Copyright 2018 Optos plc All rights reserved ...
Page 20: ...Page 20 of 76 Part Number G108707 8GSE English Copyright 2018 Optos plc All rights reserved ...
Page 28: ...Page 28 of 76 Part Number G108707 8GSE English Copyright 2018 Optos plc All rights reserved ...
Page 74: ...Page 74 of 76 Part Number G108707 8GSE English Copyright 2018 Optos plc All rights reserved ...
Page 76: ...Page 76 of 76 Part Number G108707 8GSE English Copyright 2018 Optos plc All rights reserved ...
Page 77: ...Hrvatski Croatian optos com ...
Page 155: ...Türkçe Turkish optos com ...
Page 233: ...Ελληνικά Greek optos com ...
Page 318: ...G108707 8GSE English Croatian Turkish Greek ...