4
Applications
104
Total Station DTM-302 Series Instruction Manual
7.
Enter a PT (and CD) value. The height of
target (HT) defaults to the value used in the
last measurement.
8.
To record the corner point, press
[ENT]
.
Sample records
SS, 58, 0.0000, 48.3304, 169.19165, 82.02470, 10:52:37, FLOOR2
CO, PT1, 1.0080, 48.3020,169.19165, 83.58565
CO, PT2, 1.0080, 48.3155,128.54250, 85.42440
CO, O/S MSR:40 0.0000 0.0000 169.20370 87.02340
Measuring circle offsets
40.1
1.
To enter the circle center calculation function,
press
[7]
or select
Circle
in the Offset menu.
If you have not taken a measurement to the
circle before entering this function, a
temporary measurement screen appears.
2.
Sight any point on the surface of the circle and
press
[MSR1]
or
[MSR2]
.
The calculated corner point is stored as an SS record.
The next three or four comment records are measured points. For example:
CO, Point name (fixed to PT1, PT2 etc.), HT, SD, HA, VA.
If you use a prism attached to the surface of the circle for the distance
measurement, press the
+SD
softkey to eliminate the offset error (from the attached
point to the measured surface of the prism) before you press
[ENT]
.
Summary of Contents for DTM-302 Series
Page 1: ...H165 E 04 8 TH 8 Total Station DTM 302 Series Instruction Manual DTM 332 DTM 352 DTM 362 ...
Page 3: ...Safety 1 In this chapter Introduction LED Safety Warnings and Cautions ...
Page 10: ...Safety x Total Station DTM 302 Series Instruction Manual ...
Page 26: ...1 Introduction 8 Total Station DTM 302 Series Instruction Manual ...
Page 40: ...2 Preparation 22 Total Station DTM 302 Series Instruction Manual ...
Page 196: ...8 System Diagrams 178 Total Station DTM 302 Series Instruction Manual ...
Page 222: ...10 Error Messages 204 Total Station DTM 302 Series Instruction Manual ...