VBA10401-R.3623.A
-
D14
・
-
Disconnect Connectors
Eyepiece unit
Metering FPC unit
#631×2
・
Take out 2 screws (#631) so that the eyepiece unit
(#B261) with the Metering FPC unit(#B2008)
attached can be removed.
・
Disconnect the FPC
①
,
②
,
③
, and
④
from each connector in order.
#B2008
#B261
#B261
#B2008
#291×2
#290
Note: The eyepiece unit (#B261) and
Metering FPC
unit
(#B2008) is attached with the adhesive. Unless
replacement is necessary, do NOT disassemble them.
In case of disassembling them or turning the screws
(#291), AE CCD position adjustment (ref. Assembly
Chapter) is necessary.
①
#B2163
②
#1026
①
#B1008
④
#B1025
2. Front Body