![Nikon AF-S VR Zoom-Nikkor ED 24-120mm f/3.5-5.6G IF Repair Manual Download Page 63](http://html1.mh-extra.com/html/nikon/af-s-vr-zoom-nikkor-ed-24-120mm-f-3-5-5-6g-if/af-s-vr-zoom-nikkor-ed-24-120mm-f-3-5-5-6g-if_repair-manual_1690555063.webp)
JAA78271-R.3598.A
- L36-4 AF-S VR24-120/3.5-5.6G -
May 17 2007
Added page
●
When the main PCB or SWM unit or MR encoder is replaced, be sure to make adjustments.
●
When the main PCB is replaced, be sure to perform "Writing of EEP-ROM Fixed Values".
How to adjust:
①
Confirm that the electric current and voltage of the connected constant-voltage power supply are set to
set values, and turn the constant-voltage power supply ON.
②
Click "Adjustment for Electrical Device" on the menu of AFSMNEW (J18342) inspection program.
(
Fig. 1
)
③
The screen for "Writing of EEP-ROM Fixed Values" appears. Click the appropriate item. (Fig.2)
④
Following the instructions on the screen, rotate the MF ring in the direction from "Infinity-end"
toward "Close-end" slowly by hand. (Fig.3)
Fig.1
Fig.2
Fig.3
Adjustment for electrical device
INC