![Nikon AF-S VR Zoom-Nikkor ED 24-120mm f/3.5-5.6G IF Repair Manual Download Page 28](http://html1.mh-extra.com/html/nikon/af-s-vr-zoom-nikkor-ed-24-120mm-f-3-5-5-6g-if/af-s-vr-zoom-nikkor-ed-24-120mm-f-3-5-5-6g-if_repair-manual_1690555028.webp)
JAA78271-R.3598.A
- L24-1・ AF-S VR24-120/3.5-5.6G -
Additional page
December. 24. 2004
LINE GENERATOR
MEGALIGHT 100
CCD camera
Lens optical alignment equipment for center (left) and periphery (right)
Attachment
holder for 4G
(J19127I)
Lens alignment equipment
(for center)
Monitor
Lens alignment
Move down slowly.
Holder-moving lever
Holder for 4th lens group (J19127I)
Stage
Screw ×4
・
Create the center positioning tool (ref. Page L24-15 for how to create it).
(Note) The tool (AF-SED24-85/3.5-4.5G) is used.
・
Create cardboard in which "Lens alignment chart" and "Viewers" are fit.
(ref. Page L24-17 for how to create it.)
(Note) The below left equipment for center alignment is NOT used for AF-S VR24-120/3.5-5.6G.
(Note)This adjustment is required when the 4th lens group is removed.
(Note) After confirming that the VR lens is locked (Vibration reduction switch is OFF), make this adjustment.
For the vibration reduction switch, refer to Page 17 of User Manual supplied with the lens.
(1) Preparation of Lens optical alignment equipment
・
Fix the holder for 4th lens group (J19127I) in the lens equipment for periphery alignment.
How to fix: Move down the holder-moving lever slowly so that the holder touches the stage. Then tighten
4 screws to fix it.
Lens alignment equipment
(for periphery)
INC