JAA78271-R.3598.A
- L17 ・ AF-S VR24-120/3.5-5.6G -
④
In case of small amplitude, lift the focus ring and #24.
Then loosen two screws (#644) to move and adjust the MR
head position
Note
:
To prevent any damages to magnetic data, do NOT let
the magnetic tape and MR head touch the magnetized
driver bit when adjusting.
《
Ref.
》
●
In case the amplitude of either CH1 or CH2 is smaller, check the screws (#644) because one of them may be
loosened.
If the screw is not loose, replace the MR head unit (B635) and readjust it because the MR head may
have troubles.
MR head
Magnetic tape
● In case a drop in the amplitude between the infinity and the close distance positions is seen, replace the magnetic
tape and readjust it because the magnetic data of the tape may be damaged.
⑤
Turn the rated voltage power OFF.
#644 × 2
C H 1 = 2 0 m V C H 2 = 2 0 m V 5 m s / d i v
A C 1 0 : 1 A C 1 0 : 1
NORM 200KS/s
C H 1 = 2 0 m V C H 2 = 2 0 m V 5 m s / d i v
A C 1 0 : 1 A C 1 0 : 1
NORM 200KS/s
INC