SAFETY PRECAUTIONS

PREPARATION - Mounting

WARNING

Indicates risk of personal injury or property damage if not followed.

Please Observe

Always follow the procedures specified below in order to prevent harm to yourself or others, and to 

prevent damage to property.

Dial gauge must be securely mounted such as on a comparator stand or magnetic base.

Please follow these guidelines.

Content marked as follows indicates risk of injury or damage if not followed

CAUTION

Denotes a prohibition – You 

MUST NOT do

Denotes a requirement – You 

MUST do

These symbols mark content that must be observed.

Read the manual and follow all instructions.

Use of product other than as described in the 
manual may cause accident.

Use only as indicator Gauge.

Use for any purpose other than measuring 
may damage or wear the instrument. 
Improper use may also cause accident.

Use in an environment which meets the 

following conditions:

Temperature within range of 0~40

°

C

humidity 30~70% (non-condensing.)

Location with minimal dust, oil, oil mist, 

and protected from direct sunlight.

Location protected from use by children 

and unauthorized people.

Use in location contrary to the above may 
cause poor accuracy, damage to the product, 
or may result in accident or injury.

Handle With Care.

Do not drop or subject to shock, do not place 
under heavy objects. Damage may cause 
failure or poor accuracy. 

Make sure Gauge holder is rigid. 

Holder must be sufficiently secure to prevent deflection 
from the weight of the Gauge.

Holder must be rigid enough to hold Gauge and not to 
lift from measurement force. 

Holder support arm should be as short as possible to 
prevent deflection.

Deflection or lifting will cause measurement error such 
as origin position error and inaccuracies in measured 
reading.

Dial Gauge must only be attached by Stem or Rear Lug. 

Mounting of gauge by other than Stem or Lug will cause 
inaccuracy and product damage.

During installation, do not over-tighten the Stem. 

Excessive force on the Stem may cause Spindle to bind.

Do not disassemble or modify.

It may damage Gauge and cause poor 
accuracy

If Bezel Clamp Screw is removed, internal 
components may come loose and become 
misaligned causing product failure. 

Do not shock Spindle.

Rapid motion, or lateral force may damage 
Gauge and cause poor accuracy.

Gauge Holder

Support Arm

Stem

Mounting Example

Minimize Length

No Rapid Motion

No Lateral Force

Summary of Contents for PROFESSIONAL DI-10KD

Page 1: ...n the following page Limit Markers For marking acceptance range for Pass Fail testing Pointer Needle Shows measurement on Main Scale Main Scale Main Scale rotate Bezel to turn Bezel Clamp Screw Clamps Scale to prevent rotation Revolution Counter Pointer indicates Main Scale 100 Rev Counter Scale Each division is Main Scale 100 Stem For holding and mounting Gauge Spindle Shaft moves up and down wit...

Page 2: ...n and unauthorized people Use in location contrary to the above may cause poor accuracy damage to the product or may result in accident or injury Handle With Care Do not drop or subject to shock do not place under heavy objects Damage may cause failure or poor accuracy Make sure Gauge holder is rigid Holder must be sufficiently secure to prevent deflection from the weight of the Gauge Holder must ...

Page 3: ...nd move it out of the way during operation to prevent interference HOW TO USE Comparison Measurements Set Up Reference Part Carefully lift Spindle with fingertip and taking care not to hit Spindle from the side insert the Reference Part or Master under Contact Point Set the Origin Adjust the gauge mount or rotate the Bezel to set the Gauge to 0 Remove Reference and begin measurements Remove Refere...

Page 4: ...there is no force on the Spindle such as pushed in or lateral force Keep away from moisture and direct sunlight and secure from unauthorized personnel I360 K 1803 Niigata seiki Co Ltd 6 15 22 Tsukanome Sanjo Niigata Japan 955 0055 Tel 81 256 31 5670 Fax 81 256 39 7730 MAIL intl sales niigataseiki co jp URL http www niigataseiki co jp CALIBRATION Replacement Contact Point Part No DI 10KD DI 10 DI C...

Reviews: