background image

Thank you for purchasing Niigata Seiki Digital Calipers.

This is a precision measuring tool for making Inside, Outside, Step Height, and Depth measurements.

For safe and proper use, please read this instruction manual before use and follow the procedures described. 

Please keep manual where it is accessible to user for future reference.

Keep this manual with the instrument if transferred or leased to a third party.

For inquiries about this product, please contact dealer or Niigata Seiki.

PART IDENTIFICATION AND FUNCTION

LEFT HAND DIGITAL VERNIER CALIPERS

PRECISION MEASURING TOOLS

D-***HL

Model No.

User Manual

Object to be measured is positioned between these surfaces.

For measuring outside dimensions.

Measures height of steps.

For measuring inside dimensions.

Position surfaces inside object to be measured.

For measuring depth.

Depth is measured between these two surfaces.

Supports LCD Display Unit.

Tighten to Prevent the Slide and Display from moving.

Displays digital measurement.

Open to access battery.

When pressed, Display will read "0.00".

For turning power ON/OFF.

Measuring Surfaces for outside measurements

Outside Jaws

………………………………………

Measuring surfaces for step measurements

……

Inside Jaws

…………………………………………

Measuring surfaces for inside measurements

……

Depth Bar

…………………………………………

Measuring surfaces for depth measurements 

……

Scale

………………………………………………

Lock Screw

………………………………………

LCD Display

………………………………………

Battery Cover

……………………………………

[ZERO] Button

……………………………………

[ON/OFF] Button

…………………………………

SAFETY PRECAUTIONS

Please Observe

To prevent harm to yourself or others, and to prevent damage to 

property, always follow the procedures marked by the following 

symbols.

Read the manual and follow the directions.

Use of product other than as described in this manual 

may cause accident.

Use only for measuring.

Use for any purpose other than measuring may 

damage or wear the instrument. Improper use may 

also cause accident.

Handle with Care.

Do not drop or subject instrument to excessive shock. 

Do not place under heavy objects. Improper handling 

may cause damage or poor accuracy. 

Do not scratch instrument, for example by writing ID 

number.

Avoid using in high electric fields, such as near 

fluorescent lights or switching power supplies.

Incorrect value may be displayed on LCD.

Indicates risk of personal injury or property damage if not followed.

WARNING

Denotes a prohibition - 

You MUST NOT do

Denotes a requirement - 

You MUST do

Use and store only in environment meeting the 

following conditions:

Dry location protected from rain, water, and oils.

Location that is not excessively hot.

Location protected from use by children and 

unauthorized people.

Use in places contrary to the above may cause 

damage to the product resulting in accident or injury.

Jaw Tips Are Sharp

̶

Handle With Care.

Careless handling may cause injury.

Do not disassemble or modify.

Disassembly may damage product or cause accident. 

For repair, please contact distributor .

Do not write on instrument with electric engraver.

Do not engrave instrument body or jaw, such as an ID 

number with engraver or electric pen.

INSERTING

REPLACING BATTERY

AFTER USE CARE

STORAGE

TROUBLESHOOTING

SERVICE

After use, wipe off any dirt or oil from 

measuring surfaces, sliding surfaces, and 

exterior using a dry cloth and perform rust 

prevention treatment.

For rust prevention, lightly apply anti-rust oil, or place in 

rust preventive bag.

Store with Jaws slightly open.

If Jaws are closed, expansion due to temperature changes 

may cause excessive force which will cause inaccuracy.

Store in a cool, dry, and dark location in the 

provided case.

Keep out of direct sunlight and moisture, and please 

keep secure from unauthorized personnel.

Remove battery if Caliper will not be used for a 

long period of time.

Batteries may leak if left in unused instrument for an 

extended period.

PREPARATION FOR USE

Before using the calipers, please follow the steps below:

Wipe off rust proofing and dirt from measuring 

surfaces and slide.

Contamination of surfaces may cause measurement 

error.

Allow the calipers and object to be measured 

time to reach the same temperature.

A temperature difference between the object to be 

measured and the caliper may cause measurement 

error. Allow enough time for the temperatures to 

equilibrate.

HOW TO USE

Power ON/OFF

To turn on, press the [ON/OFF] Button.

To turn off, press the [ON/OFF] Button.

Power will automatically turn OFF after about 20 minutes with no 

activity. Press the [ON/OFF] Button or move the Slide to turn ON.

Absolute Measurement Mode

Loosen the lock screw, and turn on power.

With jaws closed, press the [ZERO] Button.

When 

0.00mm

 is displayed on LCD, Calipers is ready to 

start measurement.

Comparisons Measure Mode

Loosen the lock screw, and turn on power.

With jaws open to desired reference position (any point 

is OK,) press [ZERO] Button.

When 

0.00mm

 is displayed on LCD, Calipers is ready 

to start measurement.

Q. Nothing is displayed on LCD.

A. The battery may be running low, please replace 

battery with a new one.

Q. With power on, the number on the LCD does not 

change as Display Unit is moved.

A. Please reset by removing battery for about 30sec., 

and then replacing.

Q. Nothing happens when buttons are pressed.

A. Make sure battery is properly inserted.

Q. The correct value is not displayed.

A. High humidity may cause dampness. Please dry off 

the instrument and use only in dry location.

 Slide cover in direction of arrow.

 Insert battery with (+) side outward.

 Replace battery cover.

Use only SR44 type battery.

Notice

Not including quantization error (

±

1 count)

If Instrument is not working properly, or if you have any 

questions, please contact distributor.

Please note, manufacturer is unable to respond to 

inquires or provide service directly. Please contact 

distributor .

Niigata seiki Co., Ltd.

5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055
Tel. : +81-256-33-5522   Fax. : +81-256-33-5518

MAIL   [email protected]

URL    http://www.niigataseiki.co.jp

PRODUCT SPECIFICATIONS

Resolution :  0.01mm

Display  :  5 Digit LCD

Auto Off : approx.20 min.

Maximum response speed : Slide to Right .....1.5 m/s

            

   Slide to Left .......0.75 m/s

Left/Right as shown in diagram at top of manual.

Operating Temperature Range :      0

°

C

~

40

°

C

Storage Temperature Range  :  

10

°

C

~

60

°

C

Power :  (1x) SR44 Silver oxide Battery

Battery Life :  approx. 1 years in normal use

Accessory  :  SR44 Silver oxide Battery (for test)

±

0.03

mm

±

0.04

mm

Model No.

Measuring

Range

Maximum

permissible error

Weight

D-150HL
D-200HL
D-300HL

150g
190g
250g

0 -150

mm

0 -200

mm

0 -300

mm

Remove

Battery

Cover

Measuring surfaces for

outside measurements

Outside Jaws

Measuring surfaces

for step measurements

Measuring surfaces for 

inside measurements

LCD Display

Scale

Lock Screw

Battery Cover

Depth Bar

Model D-150HL shown.

Measuring surfaces

for depth measurements

Inside Jaws

[ON/OFF] Button

[ZERO] Button

Summary of Contents for D HL Series

Page 1: ...place in rust preventive bag Store with Jaws slightly open If Jaws are closed expansion due to temperature changes may cause excessive force which will cause inaccuracy Store in a cool dry and dark location in the provided case Keep out of direct sunlight and moisture and please keep secure from unauthorized personnel Remove battery if Caliper will not be used for a long period of time Batteries m...

Page 2: ...や油などを乾いた ウエスで拭き取り 防錆処理を行う 防錆処理は防錆油を薄く塗るか 防錆袋などに入れてくだ さい ジョウを少し開いた状態で保管する ジョウを閉じた状態で保管すると 温度変化による膨張 などで無理な力がかかり 精度不良の原因となります 付属のケースに入れ 乾燥した冷暗所に保管する 直射日光や湿気は避け 管理者以外が触れない状態で保 管してください 長期間使用しない場合は電池を製品から取り外した 状態で保管してください 長期間使用しないで放置すると 電池の液漏れの原因と なります 使用前の準備 ご使用前に 下記の準備を行ってください 測定面 摺動面 外観などの汚れや防錆油などを拭 き取る そのまま測定を行うと誤差の原因となります 本体と被測定物の温度慣らしを十分に行う 測定器本体と被測定物の間に温度差があると 誤差の原因 となります 同じ温度になるよう 温度慣らしは十分に行っ て...