9
3
3.
CHECK/ADJUSTMENT PROCEDURE
3.1
Outline of Check/Adjustment Procedure
1. Size adjustment
2. Bevel position adjustment
3. Final check
3.2
Size Adjustment
1
Process CR39 lenses in the beveling mode and flat edging mode, and then check their
sizes.
1) Recall the
∅
45 built-in data, set SIZE
at 0.00, and then process a lens in the
beveling mode.
To recall the 45 built-in data, press the
[
∅
45] button on the MENU screen.
2) Replace with a new lens, recall the
∅
45 built-in data, set SIZE at 0.00, and
then process a lens in the flat edging
mode.
3) Measure the outer diameter of the finished lens.
When the finished lens is in the range of 45.00±0.03, size adjustment is not necessary. When not in
the range above, check and adjust the size with a polycarbonate lens following step 2 and later.
•
Processing conditions may vary with the transport/setting conditions of the system. Check
and adjust the processing conditions, and complete the check list (copy of Sec. 4).