38

UL LISTING INFORMATION

POWERDRIVE FX Installation guide

4729 en - 2017.08 / c

NOTES

Summary of Contents for POWERDRIVE FX 100T

Page 1: ...POWERDRIVE FX Installation guide 4 quadrant Variable speed drive Part number 4729 en 2017 08 c...

Page 2: ...d to be able to supply a motor and the driven machine above its rated speed If the motor or the machine are not mechanically designed to withstand such speeds the user may be exposed to serious danger...

Page 3: ...components during transportation and handling Avoid touching electronic components and contact parts The variable speed drives contain parts which are sensitive to electrostatic stresses and may be e...

Page 4: ...c Axial output Helical gears Motors Gearboxes POWERDRIVE FX RFI filter Encoder or resolver input Additional I O Datalogger Communication options Options HPM motor Motor options MDX KEYPAD MDX SOFT par...

Page 5: ...1 STO 2 inputs Safe Torque Off function 22 3 3 1 3 phaseAC power supply in accordance with safety standard IEC EN62061 2005 and EN ISO 13849 1 2006 Single channel locking SIL1 PLb 22 3 3 2 3 phaseAC p...

Page 6: ...back options 29 5 2 5 I O options 29 5 3 RFI filters 30 5 3 1 General 30 5 3 2 Weight and dimensions 30 6 TRIPS DIAGNOSTICS 31 6 1 Drive statut 31 6 2 Alarms 32 6 3 Trips 32 7 MAINTENANCE 35 7 1 Servi...

Page 7: ...ck POWERDRIVE FX drives are designed for installation in a cabinet or an enclosure to ensure protection from conducting dust and condensation Prevent access by unauthorised personnel Diagram Micro con...

Page 8: ...fuges translation of travelling cranes etc Normal duty For low overload constant torque or centrifugal torque machines fans compressors etc Current available for 60 seconds every 600 seconds The outpu...

Page 9: ...9 GENERAL INFORMATION POWERDRIVE FX Installation guide 4729 en 2017 08 c Notes...

Page 10: ...In atmospheres where condensation may form install a heating system to be switched off when the drive is operating It is advisable to control the heating system automatically The casing of the POWERD...

Page 11: ...750 692 766 782 788 45 284 78 5 53 5 32 5 49 5 37 4 Lifting rings Fixed with 4 M8 screws Terminal block cover Terminal block cover Front view Side view Dimensions in mm With MDX I O M2M option add 25...

Page 12: ...with its fixing feed mounted ready for surface mounting For through panel mounting remove the feet and follow the instructions below 2 2 2 1 Ratings 33T to 50T 530 200 18 495 553 486 140 15 40 231 fo...

Page 13: ...5 78 5 49 5 700 6 for M8 crimp cap nuts Solid surface Back of the cabinet Lifting rings Terminal block cover Terminal block cover Drill hole diagram Side view seal seal 53 5 Dimensions in mm With MDX...

Page 14: ...ow rate and noise levels Losses Losses W POWERDRIVE FX 33T 40T 50T 60T 75T 100T Total 800 980 1150 1450 1850 2200 Inside the cabinet through panel mounting 90 100 110 140 170 200 Maximum losses for no...

Page 15: ...15 MECHANICAL INSTALLATION POWERDRIVE FX Installation guide 4729 en 2017 08 c Notes...

Page 16: ...short circuits The drive stop function does not protect against high voltages on the terminal blocks Check that the voltage and current of the drive the motor and the mains supply are compatible Afte...

Page 17: ...U V W PE Screw bolt M8 Tightening torque 12 Nm Screw bolt M8 Tightening torque 12 Nm QS Mains supply Optional RFI filter Optional sensor 3 phase motor asynchronous or synchronous MDX ENCODER and or Fi...

Page 18: ...5 3x25 15 59 48 80 125 100 3x25 16 73 3x25 16 50T Heavy 68 55 80 125 3x25 16 59 48 80 125 100 3x25 16 73 3x25 16 Normal 83 66 100 160 3x25 16 72 57 100 160 125 3x25 16 86 3x25 16 60T Heavy 83 66 100 1...

Page 19: ...l blocks 3 2 2 1 Characteristics of the PX1 terminal block 1 10V 10 V internal analog source Accuracy 2 Maximum output current 10 mA 2 AI1 Differential analog input 1 3 AI1 Differential analog input 1...

Page 20: ...is used to maintain the control power supply in the event of mains loss 2 DO1 Digital output Factory setting Zero speed Characteristics Open collector Absolute maximum voltage 30 V 0 V Overload curre...

Page 21: ...tings The STO 1 and STO 2 inputs must be closed before giving a run command By default the motor sensor detection is disabled If the motor thermal sensor needs to be connected to DI1 CTP set Mtr 06 05...

Page 22: ...iagrams described in the following paragraphs must be implemented The STO 1 STO 2 inputs are safety components which must be incorporated in the complete system dedicated to machine safety As for any...

Page 23: ...of R F signals on the power supply cable conducted emissions By direct radiation near to the mains supply power cable or the drive motor cable radiated emissions These phenomena are of direct interest...

Page 24: ...its impedance is as low as possible so as to distribute the fault currents and high frequency currents without them passing through electronic equipment Metal grounds must be mechanically connected to...

Page 25: ...EN 61000 3 Emission Standard Categories Size 2 Size 3 Size 2 or 3 with external filter EN 61800 3 C1 To be defined C2 Cable length 10 m Frequency 5 kHz Cable length 10 m Frequency 5 kHz Cable length...

Page 26: ...e particular applications As soon as it is swithched on the MDX KEYPAD is set to read mode The buttons are used to scroll through the all parameters required for supervision and diagnostics Motor curr...

Page 27: ...ters can be set using the Parameter setting Parameter setting via the keypad menu Control via the keypad is disabled in factory set configuration Trip history Gives a quick overview of the drive s las...

Page 28: ...nal modules Several options can be combined Fieldbus options see section 5 2 3 Speed feedback options see section 5 2 4 I O options see section 5 2 5 5 2 3 Fieldbus options Depending on the configurat...

Page 29: ...umentations 5 2 5 Additional I O options Two options are available to increase the number of inputs outputs of the Powerdrive FX MDX I O Lite MDX I O M2M Functions MDX I O Lite MDX I O M2M Analog inpu...

Page 30: ...3359 180 28 197 6 34 CAUTION The specific design of these filters makes it possible to use them in the context of installations with a neutral IT point connection The installer must however check that...

Page 31: ...2 not connected or 06 15 Drive output set to Inhibit Depending on the control logic selected in 06 04 Ctr 06 the motor can start as soon as the drive is enabled OP 1 Drive enabled motor on load 2 Driv...

Page 32: ...cel the trip If the Run FWD or Run reverse terminal is closed at the time of resetting the motor may or may not start immediately depending on the setting of Ctr 06 06 04 No Reason for trip Possible c...

Page 33: ...current reference on analog input AI3 30 Loss of communication on the P2 connector serial link Check the cable connections Check the parameter 11 63 is compatible with the timing of requests from the...

Page 34: ...verheating of phase W IGBTs 60 A problem is detected during the control board and interface test Refer to parameters 17 05 17 08 and 17 09 in the diagnostics menu in commissioning manual ref 4617 63 T...

Page 35: ...ing maintenance work on the drive There are very few maintenance and repair operations to be performed by the user on POWERDRIVE FX drives Regular servicing operations are described below 7 1 Servicin...

Page 36: ...id state overload protection for the motor load The drive provides overspeed protection However it does not provide the level of protection afforded by an independent high integrity overspeed protecti...

Page 37: ...37 UL LISTING INFORMATION POWERDRIVE FX Installation guide 4729 en 2017 08 c NOTES...

Page 38: ...38 UL LISTING INFORMATION POWERDRIVE FX Installation guide 4729 en 2017 08 c NOTES...

Page 39: ......

Page 40: ...Moteurs Leroy Somer Headquarter Boulevard Marcellin Leroy CS 10015 16915 ANGOUL ME Cedex 9 Limited company with capital of 65 800 512 RCS Angoul me 338 567 258 www leroy somer com IMP297NO582...

Reviews: