![Nidec POWERDRIVE FX 100T Installation Manual Download Page 34](http://html1.mh-extra.com/html/nidec/powerdrive-fx-100t/powerdrive-fx-100t_installation-manual_1687880034.webp)
34
TRIPS - DIAGNOSTICS
POWERDRIVE FX Installation guide
4729 en - 2017.08 / c
No.
Reason for trip
Possible cause and corrective actions
49 User trip 9 triggered by the serial link
10.38
= 49
-
50
User trip 10 triggered by the serial link
10.38
= 50
51
The DO2 output load current (MDX-I/O option) is > 200 mA Check that DO2 is not short-circuited
52 The DO3 output load current (MDX-I/O option) is > 200 mA Check that DO3 is not short-circuited
53
Communication problem between the drive and the
MDX-I/O option
Check the MDX-I/O option mounting
54
Communication problem between the drives
-
56
Internal protection of phase V IGBTs
Check the motor and cable insulation
57
Internal protection of phase W IGBTs
58
Overheating of phase V IGBTs
• Clean the cabinet dust filters
• Check the drive ventilation units are working correctly
• Check that the product air inlet temperature is not outside
the limits
• If the trip appears at frequencies lower than 10 Hz, check
that the limit conditions given in section1.4.3 have been
complied with
59
Overheating of phase W IGBTs
60
A problem is detected during the control board and
interface test
Refer to parameters
17.05
,
17.08
and
17.09
in the
diagnostics menu in commissioning manual ref. 4617
63 The STO-1 and STO-2 inputs have had a different state for
more than 100 ms.
Check the remote control link for the STO-1 and STO-2
inputs
65
Overload on the +10 V power supply
Check the I/O wiring
66
The DO1 output load current is > 200 mA
Check that DO1 is not short-circuited
67 The internal ventilation is not working (50T and 100T only)
Get in touch with your usual LEROY-SOMER contact
68
The current has exceeded the limit programmed in
05.55
.
The load is too high for the setting
-
69
The 24V load current is too high
Check the MDX-I/O option I/O wiring
70 Loss of the current reference on analog input AI4 of the
MDX-I/O option
Check the input wiring and source of the MDX-I/O option
71
Loss of the current reference on analog input AI5 of the
MDX-I/O option
Check the input wiring and source of the MDX-I/O option
101 Mains loss
• Check the input fuses
• Check the quality of the power supply (voltage dips)
102
Loss of rectifier synchronisation with the mains
Check the quality of the power supply (commutation
notches)
Summary of Contents for POWERDRIVE FX 100T
Page 1: ...POWERDRIVE FX Installation guide 4 quadrant Variable speed drive Part number 4729 en 2017 08 c...
Page 9: ...9 GENERAL INFORMATION POWERDRIVE FX Installation guide 4729 en 2017 08 c Notes...
Page 15: ...15 MECHANICAL INSTALLATION POWERDRIVE FX Installation guide 4729 en 2017 08 c Notes...
Page 37: ...37 UL LISTING INFORMATION POWERDRIVE FX Installation guide 4729 en 2017 08 c NOTES...
Page 38: ...38 UL LISTING INFORMATION POWERDRIVE FX Installation guide 4729 en 2017 08 c NOTES...
Page 39: ......