Electric Power Generation

2019.10 / e

Installation and maintenance

R180

AVR

5599 en -

SAFETY MEASURES

Before using your machine for the first time, 

it is important to read the whole of this 

installation and maintenance manual.

All necessary operations and interventions 

on this machine must be performed by a 

qualified technician.

Our technical support service will be pleased 

to provide any additional information you 

may require.

The various operations described in this 

manual are accompanied by recommenda-

tions or symbols to alert the user to potential 

risks of accidents. It is vital that you unders-

tand and take notice of the following warning 

symbols.

Warning symbol for an operation capable 

of damaging or destroying the machine 

or surrounding equipment.

 

Warning symbol for general danger to 

personnel. 

Warning symbol for electrical danger to 

personnel.

All servicing or repair operations perfor-

med on the AVR should be undertaken by 

personnel trained in the commissioning, 

servicing and maintenance of electrical 

and mechanical components.

 

When the generator is driven at a 

frequency below 28 Hz for more than 30 

seconds with an analogue AVR, its AC 

power supply must be disconnected. 

WARNING

This AVR can be incorporated in a EC-

marked machine.

This manual is to be given to the end 

user.

© - We reserve the right to modify the 

characteristics of this product at any time in 

order to incorporate the latest technological 

developments. The information contained in 

this document may therefore be changed 

without notice.

This document may not be reproduced in 

any form without prior authorisation.

All brands and models have been registered 

and patents applied for.

WARNING

This manual concerns the alternator AVR which you have just purchased.

We wish to draw your attention to the contents of this maintenance manual.

Summary of Contents for Leroy-Somer R180

Page 1: ...R180 AVR Installation and maintenance...

Page 2: ...arning symbol for electrical danger to personnel All servicing or repair operations perfor med on theAVR should be undertaken by personnel trained in the commissioning servicing and maintenance of ele...

Page 3: ...nge 7 4 2 Connection diagram for high voltage range with droop powered by AREP 8 4 3 Connection diagram for high voltage range with droop powered by PMG 9 5 AVR SETTINGS 10 6 TROUBLESHOOTING CHART 11...

Page 4: ...and 5 A signal from a droop current transformer in U phase to give a voltage droop which allows the alternator to operate in parallel The R180 has an accessory input which can be used as a remote pote...

Page 5: ...xiliary input and external potentio meter range The auxiliary input range is set by the potentiometer marked Acc This potentiometer sets the maximum voltage range for the external potentiometer or the...

Page 6: ...y 10 s 350 V peak 5 Up to 75 Hz 8 Excitation current 6 A DC continuous 9 A for 5 seconds short circuit operation 9 Regulation 1 at AVR sensing terminals 10 Maximum excitation limit 6 A DC factory sett...

Page 7: ...7 Electric Power Generation 2019 10 e Installation and maintenance R180 AVR 5599 en 4 MAIN FUNCTION OF THE AVR 4 1 Connection diagram for low voltage range 0V...

Page 8: ...8 Electric Power Generation 2019 10 e Installation and maintenance R180 AVR 5599 en 4 2 Connection diagram for high voltage range with droop powered by AREP 0V...

Page 9: ...9 Electric Power Generation 2019 10 e Installation and maintenance R180 AVR 5599 en 4 3 Connection diagram for high voltage range with droop powered by PMG 0V...

Page 10: ...t the terminals using the voltage adjustment potentiometer If oscillations are seen on the voltmeter A C indicating the alternator terminal voltage gradually turn the STABILITY trimmer on the R180 clo...

Page 11: ...rnal potentiometer link open Connect link or potentiometer as necessary Loss of sensing voltage Connect as per the diagram Prime mover rpm falls Set rpm Incorrect regulation Prime mover rpm falls Set...

Page 12: ...lead to X2 The multimeter will display 0 4 V to 0 6 V Connect the red lead to Z1 The multimeter will display 0 4 V to 0 6 V Connect the red lead to Z2 The multimeter will display 0 4 V to 0 6 V Connec...

Page 13: ...potentiometer 250 V 110 V transformer 8 2 Connection Connect the 100 W bulb between the F1 and F2 terminals on the AVR Connect the 110 V transformer output to X1 and X2 on the AVR Connect the 250 V en...

Page 14: ...tage to 400 VAC The bulb will up light because the setpoint is 415 V Now turn on the switch which is connected to the 50 Hz 60 Hz input The bulb will gradually go OFF due to the change in the UFRO set...

Page 15: ...15 Electric Power Generation 2019 10 e 147 115 90 56 5 11 16 117 159 142 Installation and maintenance R180 AVR 5599 en 9 DIMENSIONS TOP VIEW SIDE VIEW...

Page 16: ...ion you may require For all spare parts orders or technical support requests send your request to service epg leroy somer com or your nearest contact whom you will find at www lrsm co support indicati...

Page 17: ...ith local legislation regarding product disposal and recycling Waste hazardous materials The following components and materials require special treatment and must be separated from the alternator befo...

Page 18: ...18 Electric Power Generation 2019 10 e Installation and maintenance R180 AVR 5599 en...

Page 19: ...ient repair support and maintenance services Trust your alternator maintenance and support to electric power generation experts Our field personnel are 100 qualified and fully trained to operate in al...

Page 20: ...www emersonindustrial com 2019 10 e www leroy somer com epg 5599 en Linkedin com company leroy somer Twitter com Leroy_Somer_en Facebook com LeroySomer Nidec en YouTube com LeroySomerOfficiel...

Reviews: