GETPARATTR
This is used to get parameter attributes such as maximum and minimum values, read-
only flag, etc.
CModeXfer
This allows the user to change the drive mode without any fitted option modules getting
a hard reset. It allows for a smoother drive mode change. While the drive mode change
occurs fieldbuses will not be able to write to parameters and this is handled at system
level. They will NOT get a ‘write to parameter failed’ message during this period.
RtuReadRegs
RtuReadParas
RtuReadInputRegs
RtuPresetRegs
RtuPresetParas
RtuMasterReply
RtuMasterStatus
These commands are implemented to allow the user to utilise the SM-Applications,
SM-Applications Plus and Digitax ST Plus modules Modbus RTU master functionality.
Refer to the on-line help for further details.
PFIXREAD6/PFIXWRITE6
These blocks provide reading and writing of drive parameters in a fixed precision of 6
decimal places.
SETUSERID
This command is used to set the User ID Pr
81.49
.
ANSIREPLY
This command existed in the UD70, however the syntax has changed for the Second
Processor.
It is a EIA-RS485 port function which is used in conjunction with the ANSIREAD and
ANSIWRITE functions.
(Max%, Min%, Flags%) = GETPARATTR(Menu%, Par%)
Menus 15 to 20 will not be defaulted when using this command.
SETUSERID(101) // set #81.49 to 101.
(Status%, Reply%) = ANSIREPLY()