This parameter allows a 1ms delay to be introduced between the Second Processor
enabling the EIA-RS485 transmitter and actually commencing the transmission. This
should only be required if it is found that the recipient of the transmission is receiving a
corrupted start of message.
This parameter is available on SM-Applications Lite module, SM-Applications Lite V2
module and Digitax ST Indexer but is not allowed to be set to a 1 (On). Controls where
the output of the DPL PRINT command is sent. If set to zero (Off), the output is sent to
the programming client (SyPTPro) and if set to 1 (On) it will be sent to the EIA-RS485
port.
Defines the scheduling period (tick-time), in milliseconds, for the DPL CLOCK task. A
value of zero will disable the CLOCK task.
Pr 81.09
EIA-RS485 Tx Enable Delay
Access
RW
Range
0 to 1ms
Default
0ms
Update Rate
Initialization
Apps
Apps Lite Apps Plus
Lite V2
ST Plus
ST Indexer
Pr 81.10
DPL Print Routing
Access
RW
Range
0/1
Default
0
Update Rate
Initialization
Apps
Apps Lite Apps Plus
Lite V2
ST Plus
ST Indexer
0=
1=
0=
1=
0=
1=
0=
1=
0=
1=
0=
1=
Pr 81.11
Clock Task Scheduling (ms)
Access
RW
Range
0 to 200ms
Default
10ms
Update Rate
Initialization
Apps
Apps Lite Apps Plus
Lite V2
ST Plus
ST Indexer
Prior to version 01.05.00 Unidrive SP the default for this parameter was 0ms (disabled).