60
SM-Applications Modules & Motion Processors User Guide
Issue Number: 4
These 2 parameters (Pr
90.45
& Pr
90.46
) must be set to 1 to allow the marker flags
(Pr
90.41
and Pr
90.42
) to be set when the marker pulse is activated.
These 2 parameters (Pr 90.47 & Pr 90.48) must be set to 1 allow the freeze flags
(parameters Pr
90.18
and Pr
90.28
) to be set when the freeze input is activated.
This parameter shows the error ID of an APC runtime error. This will be set when
module trip 81 occurs. Brief descriptions of the error codes are shown in the following
table. For more information, refer to the
Advanced Position Control User Guide
.
Pr 90.46
Feedback Marker Flag Enable
Access
RW
Range
0/1
Default
N/A
Update Rate
Immediate
Apps
Apps Lite Apps Plus
Lite V2
ST Plus
ST Indexer
Pr 90.47
Reference Freeze Enable
Access
RW
Range
0/1
Default
N/A
Update Rate
Immediate
Apps
Apps Lite Apps Plus
Lite V2
ST Plus
ST Indexer
Pr 90.48
Feedback Freeze Enable
Access
RW
Range
0/1
Default
N/A
Update Rate
Immediate
Apps
Apps Lite Apps Plus
Lite V2
ST Plus
ST Indexer
Pr 90.49
APC Runtime Error ID
Access
RO
Range
32bit
Default
N/A
Update Rate
Immediate
Value Description
0
No error or failure to set up encoder object
1
CAM array too small
2
CAM segment overrun
3
CAM size has been specified as zero
4
CAM absolute reset failure
Apps
Apps Lite Apps Plus
Lite V2
ST Plus
ST Indexer