76
Digitax HD M75X Series Installation and Technical Guide
Issue Number: 5
Table 4-18 Availability of the P2 position feedback interface and the encoder simulation output
The priority of the position feedback interfaces and the encoder simulation output on the 15-way D-type is assigned in the following order from the
highest priority to the lowest.
•
P1 position interface (highest)
•
Encoder simulation output
•
P2 position interface (lowest)
For example, if an AB Servo type position feedback device is selected for use on the P1 position interface, then both the encoder simulation output
and the P2 position interface will not be available as this device uses all connections of the 15-way D-type connector. Also, if an AB type position
feedback device is selected for use on the P1 position interface and Pr
03.085
is set to a valid source for the encoder simulation output, then the P2
position interface will not be available.
Depending on the device type used on the P1 position interface, the encoder simulation output may not be able support a marker pulse output (e.g.
SC EnDat or SC SSI device types). Pr
03.086
shows the status of the encoder simulation output indicating whether the output is disabled, no marker
pulse is available or full encoder simulation is available.
When using the P1 and P2 position interfaces and the encoder simulation output together, the P2 position interface uses alternative connections on
the 15-way D-type connector. Pr
03.172
shows the status of the P2 position interface and indicates if alternative connections are being used for the
P2 position interface.
Functions
P1 Position feedback interface
P2 Position feedback interface
Encoder Simulation Output
AB Servo
FD Servo
FR Servo
SC Servo
SC SC
Commutation only
None
None
AB
FD
FR
SC
Resolver
SC Hiperface
AB, FD, FR
EnDat, SSI, BiSS
None
None
Full
SC EnDat
SC SSI
SC BiSS
AB, FD, FR
(No Z marker pulse input)
None
EnDat, SSI (with freeze input), BiSS
None
No Z marker pulse output
EnDat
SSI
BiSS
AB, FD, FR
EnDat, SSI (with freeze input), BiSS
None
None
Full
EnDat, SSI, BiSS
No Z marker pulse output
NOTE