GB
5
Courtesy light
F1
Mains power
supply
FORCE
MIN
MAX
L
N
1
2
4
3
5
CLOSE
FCC
STEP - BY STEP
SCA 24Vac
common
M1
Phototest
Services
STOP
PHOTO
OPEN
Constant resistance
STOP 8.2K
Ω
(sensitive edge)
F2
14
9
CLOSE
COMMON
OPEN
7
6
8
24V
0
10
24V
11 12 13
15
17
16
19
18
20
TL
21
22
TP
OK
AERIAL
Radio
receiver
FCA
Flashing light
OVERHEAD
GARAGE DOOR
SLIDING GATE
{
{
2.3.1) Wiring diagram
Terminal
Functions
Description
1-2
Power supply
mains power supply line
3-4
Flashing light
Output for connecting flashing light to mains voltage (Max. 100W)
5-6
Courtesy Light
Output for connection of a mains voltage lamp (Max 100W)
7-8-9
motor
motor output (Max 500VA)
10-11
24 Vac
24 Vac services power supply: Photo, Radio, ecc. (Max. 200mA)
12
Phototest
Phototest output: power supply to photocell transmitters (Max. 100 mA)
13
Common
Common for all inputs
14
A.C. Light
24 Vac output for open gate indicator light (Max. 2W)
15
OPEN limit switch
Input for connection of the OPEN limit switch.
16
CLOSE limit switch
Input for connection of the CLOSE limit switches.
(15-16)
Stop
The “Stop” input is obtained by connecting an NC-type contact serially with the limit switches
(see wiring diagram).
17
Photo
Input for safety devices with NC contact (e.g. photocells)
18
Step-by-step
Input for cyclic command (OPEN – STOP – CLOSE – STOP)
19
Open
Input for opening function (OPEN – STOP – OPEN)
20
Close
input for closing command (CLOSE – STOP – CLOSE)
21-22
constant resistance Stop
Input for “constant resistance Stop” 8.2k
Ω
(e.g. sensitive edge)
2.3.2) Description of the connections
The following table provides a brief description of the possible control unit output connections.