background image

4

2.3) Electrical connections

To safeguard the operator and avoid damaging the components while you are wiring or plugging in the various cards:

under no circumstances may the unit be electrically powered.

• Power the control unit using a 3x1.5 mm

2

cable; should the distance between the unit and the earth connection exceed 30m, install an

earth plate near the unit.

• Use wires with a minimum cross-section of 0.25 mm

2

to connect extra-low voltage safety circuits.

Use shielded wires if the length exceeds 30m and only connect the earth braid to the control unit side.

• Do not make connections to cables in buried boxes even if they are completely watertight.
• If the inputs of the Normally Closed (NC) contacts are not used, they should be jumped with the “24V common” terminal except for the

photocell inputs if the phototest function is enabled. For further information please see the “PHOTOTEST” paragraph.

• If there is more than one (NC) contact on the same input, they must be connected in SERIES.
• If the inputs of the Normally Open (NA) contacts are not used they should be left free.
• If there is more than one (NA) contact on the same input, they must be connected in PARALLEL.
• The contacts must be mechanical and potential-free; no stage connections are allowed, such as those defined as "PNP", "NPN", "Open

Collector", etc.

• The constant resistance STOP input transmits an OK signal to the control unit if a circuit with a resistance of 8.2k

(e.g. a sensitive edge)

is connected between terminals 21-22.

!

2.2) Typical system layout

In order to explain certain terms and aspects of automatic gate and overhead garage doors systems, we will now illustrate a typical sys-
tem layout.

1.

Pair of photocells (PHOTO)

2.

Flashing light

3.

Key-operated selector switch

4.

Sensitive edge

5.

Control unit A100f

In particular, please note that:
• All the photocells produced by NICE feature a SYNCHRONISATION SYSTEM that eliminates the problem of interference between two pairs

of photocells (please consult the photocell instructions for further details).

• The “PHOTO” pair of photocells have no effect when the gate is opening, while they reverse movement when the gate is closing.

1

2

FOTO

3

1

2

FOTO

4

3

4

5

5

SLIDING GATE

OVERHEAD GARAGE DOOR

2a

2b

Summary of Contents for Mindy A100F

Page 1: ...ra mindy A100F Istruzioni ed avvertenze per l installatore Instructions and warnings for the fitter Instructions et recommandations pour l installateur Anweisungen und Hinweise f r den Installateur In...

Page 2: ...nstallation This brochure which contains important directions regarding system safety should be saved for future reference along with the technical instructions for the automatic system mindy A100F Co...

Page 3: ...the electronic board from accidental contacts see figure 1a The electronic board can be interfered with only in the event of real need in this case proceed as shown in figure 1b 2 Installation Automa...

Page 4: ...s of the Normally Open NA contacts are not used they should be left free If there is more than one NA contact on the same input they must be connected in PARALLEL The contacts must be mechanical and p...

Page 5: ...ax 200mA 12 Phototest Phototest output power supply to photocell transmitters Max 100 mA 13 Common Common for all inputs 14 A C Light 24 Vac output for open gate indicator light Max 2W 15 OPEN limit s...

Page 6: ...nnected to each other in parallel with an 8 2K termination resistance Note 2 The NO and NC combination can be obtained by placing the two contacts in parallel and placing in series to the NC contact a...

Page 7: ...ntrol unit terminals 17 18 Set Dip Switch 10 to ON Phototest enabled in the future it can be disabled at any time by setting Dip Switch no 10 to OFF Pho totest disabled When using 2 pairs of photocell...

Page 8: ...ic movement stops immediately and briefly reverses direction after the device connected to the input is triggered Repeat this test for the closing manoeuvre The OK LED located in the centre of the boa...

Page 9: ...ement stops as soon as the input command stops During an opening manoeuvre movement will stop when the limit switch is trig gered during a closing manoeuvre movement will stop if the Pho tocell or the...

Page 10: ...eached In the Automatic operating mode an opening manoeuvre is followed by a pause after which the gate closes automatically The Always Close function comes into play following a power failure if the...

Page 11: ...imit switch the duration of the deceleration stage will be proportional to the Work ing Time for proper operation of the deceleration feature we recommend the installation of the limit switches During...

Page 12: ...ode Use two motors with the control units connected as indicated in fig 5 Connect the flashing light end the Gate Open Indicator to any one of the two control units setting up the connections as shown...

Page 13: ...he connection of the constant resistance STOP input the manoeuvre is enabled only if there is a voltage of 9 to 11 Vdc corre sponding to a resistance of 6150 to 10250 on terminals 21 22 The gate chang...

Reviews: