Useful range
14
Dimensions
46 x 128 h 45mm.
Operating temperature
Protection class casing
Assembly
Use in acid, saline or potentially explosive
atmosphere
Output relay contacts capacity
Failsafe category
1.5s ± 3%.
ALT output response time
PHOTO output response time
Directional capacity
TX transmission angle
Typical 8,2K
Ω
+22%/-65% for the on status (ON)
ON limits: with Rs > 2.870
Ω
and Rs < 10.010
Ω
OFF limits: with Rs < 2.590
Ω
or Rs > 11.060
Ω
Output relay contacts duration
9) Technical characteristics
In order to improve its products, NICE S.p.a. reserves the right to modify them at any time without prior notice. In any case, the manufacturer guar-
antees their functionality and fitness for the intended purposes. Note: all the technical characteristics refer to a temperature of 20°C.
FT210 technical characteristics
Type
Device for the optical status transmission of a constant resistance sensitive
edge positioned on the moving part, comprising a battery powered infrared
transmitter (TX) that is positioned on the moving leaf, to which is connected
the sensitive edge, and a receiver (RX) positioned on the fixed part.
Adopted technology
TX-RX direct optical interpolation with modulated and coded infrared beam.
Receiver power supply
12÷24Vac/dc; limits: 10÷35 Vdc; 11÷28Vac 50/60Hz; with EN 61558 insu-
lating transformer.
Receiver absorbed current
Approx. 120mA at 12Vdc; 70mA at 24Vac.
Phototest input voltage
The same limits as “Receiver power supply”.
Transmitter power supply
3.6 V with type C or AA lithium battery.
Transmitter battery life
Estimated at approx. 15 years with the type C battery, 7Ah capacity; (“resi-
dential” use: TX-RX distance up to 7m; with 20 manoeuvres per day of 90”)
Estimated at approx. 5.5 years with the type C battery, 7Ah capacity;
(“industrial” use: TX-RX distance up to 15m; with 200 manoeuvres per day
of 90”)
Estimated at approx. 6 years with the type AA battery, 2Ah capacity; (“resi-
dential” use: TX-RX distance up to 7m; with 20 manoeuvres per day of 90”)
Device input range
Sensitive (Rs)
Type D presence sensor detection capacity
Opaque objects located on the optical axis between TX and RX, larger than
50 mm and moving slower than 1.6m/s.
+/- 4° (value taken at 50% of the capacity).
RX reception angle
+/- 3° (value taken at 50% of the capacity).
approx. 210° on the horizontal axis and 30° on the vertical axis
7 m or 15m (with JP1 inserted on TX) for maximum TX-RX misalignment ±2°
(the range may be further reduced in the presence of particularly intense
atmospheric conditions: fog, rain, snow, dust, etc.)
Maximum range (under optimum conditions)
15m or 30m (with JP1 inserted on TX) for maximum TX-RX misalignment ±
2°.
<45ms (typical 31ms).
<30ms (typical 28ms).
ALT1 output response time
3 or 2 (according to the EN 954-1 standard) according to the type of the
output connections and PHOTOTEST input
Maximum 0.5A and maximum 48Vac (resistive load: cos
=1).
Mechanical life > 1.000.000 cycles; electrical > 200.000 cycles (resistive
load: 0.25A; 24Vdc).
IP44.
RX: Vertically wall mounted or on “MOCF” posts with “FA2” bracket.
TX: directly on the gate with the supplied screws.
No.
Weight
Receiver 135g.
Transmitter 165 g with FTA1 or 140 g with FTA2
-20 ÷55°C.