background image

  

9

 – English

A.4 - SEMIAUTOMATIC programming of the UP (“0”) and DOWN (“1”) limit switches

NOTES AND WARNINGS
• Use this procedure solely for awnings with mechanical Up “0” limit switch stop.

 If the limit switches have been programmed using the manual procedure (A.3), before you can use this procedure you need to perform a total or partial deletion of 

memory (A.8.1 option ‘A’ or ‘D’)”.

• After the limit positions have been programmed, the awning can be controlled by simply pressing the appropriate buttons on the control unit. The Up movement 

will be limited when the awning impacts against the mechanical lock (box) in the Upper limit switch “0”. With each impact, the height of this limit switch will be auto-
matically updated by the “Automatic limit switch update” function (paragraph 5.8). Conversely, the Down movement will be limited by the Lower limit switch “1” (limit 
switch set by the installer at a desired point).

1

2

continues

 

 

Command

an UP

movement 

0

Command

an DOWN

movement 

Hold down the button and...

... wait for the awning to be stopped when it 
collides with the box (= UP 

limit switch

 = po-

sition “

0

”). 

release the button.

Hold down the button and wait...

 2

3

4

 5

1

(x 

1

)

PRG

2

5

 sec

2

... release the button as soon as the awning 
reaches 

position “1”

 ( 

DOWN

limit switch).

Press and release 
the button (

1 time

);

count 2 movements.

Hold down the but-
ton and 

release it after 

5 sec-

onds

;

count 2 movements.

5

6

end

Finely adjust-

ing the posi-

tion of limit 

switch “1” 

1

5

 sec

3

Press the buttons until you reach the desired position.

 

Al-

ternatively

, for more accurate adjustment, run procedure 

B.1.

Hold down the button and 

release it after 

5 seconds

;

count 3 movements.

A

A.3.2 - To program the DOWN limit switch (“1”)

1

2

3

continues 

 

(x 

1

)

PRG

2

5

 sec

2

Command

an DOWN

movement 

Press and release 
the button (

1 time

);

count 2 movements.

Hold down the but-
ton and 

release it after 

seconds

;

count 2 movements.

Hold down the button and wait...

 3

4

5

end

1

Finely adjust-

ing the posi-

tion of limit 

switch “1” 

1

5

 sec

3

... release the button as soon as the awning 
reaches 

position “1”

 ( 

DOWN 

limit switch).

Press the buttons until you reach the desired position. 

Alternatively

, for more accurate adjustment, run pro-

cedure B.1.

Hold down the 
button and 

release it after 

seconds

;

count 3 movements.

Summary of Contents for E EDGE XSI 0620 LDC

Page 1: ...Tubular Motor EN Instructions and warnings for installation and use Nice E EDGE XSI 0620 LDC...

Page 2: ...Customer Service The manufacturer assumes no liability for damage to property items or persons resulting from non compliance with the assembly instructions In such cases the warranty for material def...

Page 3: ...ve the awning up or down stop it at the upper limit switch the lower limit switch or various intermediate positions it moves awnings of different weights at the same speed the up and down speeds are t...

Page 4: ...semble and install the motor refer to fig 3 the accessories shown in fig 3 are not included in the package To select the limit switch gear wheel fig 3 a drive wheel fig 3 b motor bracket fig 3 f or to...

Page 5: ...ncluded in the package CAUTION The smaller cables must be handled carefully because they contain very thin wires that could be damaged f Motor bracket not included in the package 2 screws self tapping...

Page 6: ...D done with a smartphone Programming with a smartphone with NFC Near Field Communication This technology is not yet available on this motor 4 2 Positions in which the awning stops automati cally The e...

Page 7: ...ed to disconnect all motors you do not wish to pro gram proceed as follows 1 run procedure A 1 to memorise the first transmitter on the motor you wish to pro gram 2 run procedure A 2 to deactivate all...

Page 8: ...he button 1 time the movement will stop briefly com mand received and the awning will resume its up and down movements each of random duration 5 end x 1 3 Observe the same awning and at the start of a...

Page 9: ...the system will then move the awning to the mid position During the 5 minutes at any time hold down the button and release it after 10 seconds the system will then move the awning to the mid position...

Page 10: ...stopped when it collides with the box UP limit switch po sition 0 release the button Hold down the button and wait 2 3 4 5 1 x 1 PRG 2 5 sec 2 release the button as soon as the awning reaches positio...

Page 11: ...You can memorise up to 30 H positions wherever you wish provided that these are between the two limit switch positions These positions can only be pro grammed after the limit switch positions Repeat...

Page 12: ...on Mode II see section 4 4 1 B Procedures A 6 2A and A 6 2 B memorise a single button Repeat this operation to memorise another button A 6 2 A Procedure for transmitters equipped with the PRG and ESC...

Page 13: ...nd release the button 1 time count 2 movements Press and release the button 1 time count 3 movements A English 12 A 6 2 B Procedure for transmitters without the PRG and ESC buttons When performing the...

Page 14: ...ton either the key memorised in mode 2 or the climatic conditions sensor count 5 movements option D 5 end 5 sec 5 Hold down both buttons release them after 5 seconds count 5 movements A 8 2 Procedure...

Page 15: ...ationary at the Upper limit switch 0 The following options are available sensitivity to obstacles ENABLED this setting is only active when the awning is moving Up The motor delivers a lot of force and...

Page 16: ...completely customise the movement of the awning allowing you to align mul tiple awnings of different sizes with different diameter rollers among other effects or make the awning run more quietly The...

Page 17: ...on deceleration 1 5 rotations 4 presses sets long acceleration deceleration 2 rotations 5 presses sets maximum acceleration deceleration 3 rotations Hold down the buttonand release it after 5 seconds...

Page 18: ...d to 15 Klux 4 presses sets the threshold to 30 Klux 5 presses sets the threshold to 45 Klux Press and release the button the number of times indicated in the option you have chosen 4 5 end 7 sec 1 2...

Page 19: ...seconds count 5 movements A GROUP B PROCEDURES Procedures run with the motor head buttons B 1 Precise adjustment of the UP 0 and DOWN 1 limit switch positions NOTES AND WARNINGS This adjustment can be...

Page 20: ...erface C GROUP D PROCEDURES done exclusively with a smartphone with NFC Near Field Communication NOTES AND WARNINGS The programming with the NFC technology is not yet available on this motor For more...

Page 21: ...the awning makes 2 move ments With the motor in MANUAL mode enabled with button if the user sends the com mand Sun On with button the awning moves to the above threshold position the system re starts...

Page 22: ...to cool down make sure the mains voltage corre sponds to the values indicated in the technical data chapter of this manual by measuring the voltage between the common wire and the electrical phase wir...

Page 23: ......

Page 24: ...www niceforyou com Nice SpA Via Pezza Alta 13 31046 Oderzo TV Italy info niceforyou com IDV0626A00EN_01_12_2017_DIGITAL VERSION...

Reviews: