STANDARD OPERATION
With all the dip switches turned OFF (see Fig. 1), the A0-A0/R will carry out an opening
manoeuvre with the first step-by-step or radio control pulse. This opening manoeuvre can
be stopped with the open limit switch (FCA), from the end of the work time, by another step-
by-step or radio control pulse.
The safety devices (photocell) are not contemplated in the opening manoeuvre.
The flashing light flashes throughout the entire opening manoeuvre, stopping at the end of it.
The gate or door will close when another step-by-step or radio control command is given;
this manoeuvre can be interrupted by the safety devices (Photocell), when the close limit
switch (FCC) trips or when another step-by-step or radio control pulse is given or at the end
of the work time.
The flashing light flashes throughout the entire manoeuvre, stopping at the end of it.
The sequence of the step-by-step button or radio control is:
• OPEN - STOP - CLOSE - STOP.
PROGRAMMABLE FUNCTIONS
The different functioning modes can be selected and switched on with the FUNCTIONS dip
switch:
Switch 1 ON : Courtesy light function.
Switch 2 ON : Partial remote reversal
Switch 3 ON : Complete remote reversal
Switch 4 ON : Limit switch excluded
DESCRIPTION OF THE PROGRAMMABLE FUNCTIONS
Switch 1 ON: Courtesy light function.
When this function is enabled the unit’s 4-5 output will remain active for the entire duration
of the movement plus an additional 45 seconds so a light can be connected to illuminate the
area.
Switch 2 ON: Partial remote reversal
If the safety device triggers when the gate or door is closing, movement will be reversed
partially for about 2 seconds.
11