Table 15. User-Programmable User Relays - Function Options

No.

Name

Description

9

Safety Mode Alert 

output

Activated when system is in Safety Mode or Entrapment Mode. Safety 

Mode occurs upon an impact with an obstruction. Entrapment Mode 

means gate is stopped and occurs if inherent entrapment sensor triggers 

while system is in Safety Mode.

10

Entrapment Mode 

Alert output

Activated only when system is in Entrapment Mode.

11 Unauthorized Vehicle 

Entry output

Activated when a second vehicle enters from outside without a valid 

input from an access control device. The OOLD and IOLD loops must 

be capable of being triggered at the same time for this relay to ever 

activate. This output releases when an access control input signals open 

or gate reaches the close limit position.

12

Outside Obstruction 

Vehicle Detector 

output

This output is active whenever Outside Obstruction Loop Detector is 

tripped. Interlocks an entry device to prevent pedestrian use.

13 Loitering Alert

Indicates vehicle is loitering on Outside Obstruction Loop with the gate 

closed. Adjustable from a 0 second to 135 second delay in 15-second 

intervals.

NOTE: 

LT - LOITERING ALERT adjustments can be made in Installer 

Menu

14

Gate nearing full travel 

output

Activated when gate is approaching full open or full closed. Relay 

activates  three  feet  from  where  software  expects  limit  switch  to  be 

triggered whether moving toward full open, full close, or in a reverse 

travel mode.

15 Gate Failure output

Activated to report occurence of problem. Indicates the system is in 

an Error, Fault, Alert, or Entrapment Mode. If active, gate is disabled.

16

Motor Running output

Active when motor is running and gate is in motion.

17 AC Power Failure 

output

This relay is normally energized and drops with loss of AC power.

18 DC Power Failure 

output

Activated when battery power is very low, but output ceases when 

battery is dead (18 volts). Relay is triggered when battery is less than 

21 volts.

19 Flasher Relay

Controls flashing lights to pulse once per second. Relay is constantly 

pulsing except when open limit switch is triggered. Recommended to 

use User Relay 2 since it is an electronic switch

20

Free Exit Loop Vehicle 

Detector output

Active whenever Exit Loop is tripped.

21

Inside Obstruction 

Vehicle Detector 

output

Active whenever Inside Obstruction Vehicle Detector is tripped

22

Center Loop Detector 

output

Active whenever Center (Shadow) loop detector is tripped.

VEHICLE DETECTOR

MX3640-01 Rev. E ©2020

                             

SwingSmart DC Programming and  Operations

hysecurity.com | 800-321-9947   

            

87

Summary of Contents for SwingSmart DC Series

Page 1: ...Installation and Programming Manual SwingSmart DC DC20 DCS20 Vehicular swing gate operator with Smart DC Controller...

Page 2: ...This page intentionally blank SwingSmart DC Programming and Operations MX3640 01 Rev E 2020 2 hysecurity com 800 321 9947...

Page 3: ...sed on Solar Zones 39 Important Considerations for DC Powered Operators 41 Installing the Extended Battery Backup Kit 42 DISPLAY AND MENU OPTIONS 44 Gate Handing 45 Turning Both Power Switches On 45 U...

Page 4: ...ck for High Voltage Systems 101 Access Controls and Vehicle Detector Loops 102 Installing Vehicle Detectors and Loops 102 Vehicle Detector and Loop Fault Diagnostics 105 Monitored External Entrapment...

Page 5: ...uststhegatespeedtosynchronize the left and right gates so that they reach the open and close positions at the same time Independent leaf delay adjustment for bi parting gates is selectable in second i...

Page 6: ...Cover Cover Pulley Motor Motor Brush Kit Battery Kit 50AH Battery Kit 8AH Handle Clamp Clamp Assembly Limit Plate Blocks Limit Switch Kit Bracket Limit Swith Knob Top Cover Detector Vehicle MX4535 SER...

Page 7: ...Complete Initial Setup Menu programming Review the connections on the Smart DC Controller Install Primary Secondary operator connections if the site is a bi parting gate system Attach accessory device...

Page 8: ...andle installation of HySecurity Gate vehicular gate operators A qualified installer has one of the following 1 A minimum of three years experience installing similar equipment 2 Proof of attending a...

Page 9: ...ndard covers gate operators Within this safety standard several Usage Classes are described that de ne di erent types of installations where gate operators can be applied Some operators are restricted...

Page 10: ...stalled in the area of the gate Each placard is to be visible by persons located on the side of the gate on which the placard is installed For gate operators utilizing a non contact sensor Photo Eye S...

Page 11: ...sions shall apply to Class I Class II Class III and Class IV vehicular horizontal swing gates Gates shall be designed constructed and installed so as not to create an entrapment area between the gate...

Page 12: ...tructions All sensors must be installed so that they function as intended for end use conditions UL 325 LISTING Edge sensors and photo eyes must be tested and labeled as Recognized Components or other...

Page 13: ...st Pivot Pinch Points 5 Arm Movement Installers must assess each specific site and install sensors that protect all potential entrapment zones For more information visit Gate Safety at www hysecurity...

Page 14: ...short batteries and cause potential injury Do not open or mutilate batteries Battery cells contain corrosive materials which may cause burns and other injuries Material within batteries is toxic Alway...

Page 15: ...igger IES CAUTION Do not adjust IES sensitivity to accommodate for inappropriately designed gate panels Loss of IES sensitivity increases mechanical wear on gate hardware and gate operator It may also...

Page 16: ...allows a gate to be pushed manually when the taper clamp is loosened It is recommended that you turn off DC power which disengages the motor allowing you to easily move the gate When you turn DC powe...

Page 17: ...proximately 10 to 15 seconds Variable speed open close separately Gate weight 1 300lbs 12ft leaf 590kg 4m leaf 1 300lbs 12ft leaf 590kg 4m leaf Secure Side Public Side WARNING Pedestrian gate Make sur...

Page 18: ...sign also provides a 9 6 inch 24 4cm height between the control box and chassis base for pulling and placement of wires CAUTION Be sure to restrict conduit to the 6 x 7 inch 15 2 x 17 7cm cutout in th...

Page 19: ...nduit is permissible but not recommended because it can impair the strength of the chassis and void the Limited Warranty UNPACKING THE OPERATOR Prepare the gate operator for installation See Figure 4...

Page 20: ...dimension at 30 35 or 40 76 89 or 102cm 3 Set the operator base on the concrete pad and use it as a template Position the operator base so the center mark on the pad aligns with the small hole in the...

Page 21: ...racket CAUTION Consider positioning the operator so existing conduit exits through the cutout in the SwingSmart base plate Cutting small holes in the base plate for pre existing conduit is permissible...

Page 22: ...e taper clamp assembly using the fasteners removed in step 2 4 Pull the taper handle to lengthen it Adjust the handle so the ball detent fits into its cutout and secures the handle length Turn the han...

Page 23: ...ches 121cm A B INSTALLATION Table 3 Gate Linkage Arms Installation Dimensions Short Gate Installation For gates up to 10 feet 3 meters X Y Xg A B 10 5 27cm 14 36cm 23 5 60cm 15 5 39cm 21 5 55cm 18 46c...

Page 24: ...71cm 40 5 103cm 120 32 81cm 20 51cm 41 104cm 31 5 80cm 44 112cm 130 38 97cm 18 46cm 44 112cm 36 91cm 47 5 121cm NOTE Maximum A 38 97cm NOTE Maximum B 47 5 121cm NOTICE The linkage tubes used for the a...

Page 25: ...the pivot bolt is not vertical binding of the arm assembly may occur during operation Set screw The set screw serves as a physical stop when the gate is closed Middle set screw hole allows a slight be...

Page 26: ...ust the limit cams use a Phillips head screwdriver and loosen the fastener that secures each limit cam to the limit plate 3 Manually open and close the gate Move the limit cams so they trip the approp...

Page 27: ...the elbow with a slight offset at the full close position Use the supplied set screw in middle position to prevent the arm from locking The intent of the offset is that upon gate strike the elbow wil...

Page 28: ...es not recommend it The preferred method is an installation where the gate arm remains horizontal throughout gate travel z A gate must be neutrally balanced To comply with ASTM F2200 General Requireme...

Page 29: ...ing the taper clamp until after the operator has been configured to run Refer to Configuring the Setup Menu on page 47 1 To loosen and release the taper clamp extend the taper handle and turn the hand...

Page 30: ...nds the motor turns off and the buzzer continues for another 30 seconds ALERT 1 FORCED OPEN appears on the display An OPEN or CLOSE command clears the alert and resets the display z Fully straighten t...

Page 31: ...CE Properly grounding the gate operator is critical to gate operator performance and the life of its electrical components Use sufficient wire size during installation If you do not ground the operato...

Page 32: ...d to the 230V position or damage to the operator will occur and void the Limited Warranty Figure 18 Wiring AC Power Voltage selector switch is factory set to 115V If power input is 208 230V move the s...

Page 33: ...e wire size be increased or the distance of the run be decreased To connect to 115VAC power take the following steps 1 Make sure the AC power is turned off at its source and the DC and AC power switch...

Page 34: ...ion cover and secure it NOTICE Table 6 assumes a dedicated circuit Additional loads require that the wire size be increased or the distance of the run be decreased 4 Access the input power wires by re...

Page 35: ...n charger which allows a 24V solar panel or two 12V panels a direct connection to the SwingSmart operator with no additional electronic devices required To plan a solar powered site read through this...

Page 36: ...ries z Solar hours at the site Solar hours relate to the amount of energy delivered by the sun and absorbed by the solar panels It is NOT the same as the number of daylight hours available at the site...

Page 37: ...rimp bond the equipment ground wire to the green ground wire in the junction box 6 Slide the plastic cover off the control box and attach the red spade connector to the battery terminal on the upper D...

Page 38: ...Solid state 24VDC 24VDC 12VDC 12VDC Press button to light active inputs COM B A DUAL GATE COM OPEN 24V RADIO OPTIONS S1 COM NO USER2 DC Amp Draw on Power Supplies Two power supplies are available 24VD...

Page 39: ...hich usually draw at minimum 0 009A Understanding Gate Activity based on Solar Zones Use the solar maps to determine the number of solar hours per day that can be reasonably expected in a particular z...

Page 40: ...with the gate travel occurring throughout the night determines the battery capacity required The number of amps that the peripherals draw coupled with the gate travel during the day determines the sol...

Page 41: ...ries contain sulfuric acid Acid in your eyes on your skin or on your clothing can cause injury and severe burns If batteries are dropped or damaged dispose of them properly POWER z Batteries are rated...

Page 42: ...ully rotate the support tray to access the battery wires Lift the 8Ah batteries from the support tray Disconnect the black and blue wires and set the 8Ah batteries aside 6 Return the support tray to i...

Page 43: ...1 Start at a gate status display 2 To access the User Menu press the MENU button twice 3 Access the Installer Menu by simultaneously pressing the OPEN and RESET buttons 4 Use NEXT to navigate to the m...

Page 44: ...he field A S T A R T User Guide is also available online CAUTION Smart DC Controller can be powered when either switch is turned on The operator is a DC powered unit and runs on its batteries If DC po...

Page 45: ...the Setup Menu z Error message indicates a problem exists with the operator which needs to be resolved before the operator can function properly Left Handing Right Handing NOTICE If AC power is lost...

Page 46: ...ESET button or cycling power Faults indicate a need for diagnosis and resolution Refer to Smart DC Controller Troubleshooting on page 115 Figure 30 Function of the Smart DC Controller Buttons in Menu...

Page 47: ...enu Refer to Reinstating Factory Defaults on page 74 Figure 31 Configuring the Setup Menu SH 0 GATE HANDING OPEN CLOSE STOP MENU RESET PREV NEXT SELECT UC 0 USAGE CLASS OPEN CLOSE STOP MENU RESET PREV...

Page 48: ...GATE STOPPED OPEN CLOSE STOP MENU RESET PREV NEXT SELECT HYSECURITY GATE CLOSED OPEN CLOSE STOP MENU RESET PREV NEXT SELECT HYSECURITY GATE OPEN OPEN CLOSE STOP MENU RESET PREV NEXT SELECT VIEWING OPE...

Page 49: ...n a dual gate setting whether operator is set to Primary or Secondary Setting is assigned in Installer Menu Operator Type OT OT 12 SwingSmart DC or DCS Indicates and identifies the operator Set Handin...

Page 50: ...not counted Displays number of cycles gate operator has incurred Similar to an odometer it resets to zero after 999 999 cycles Close Timer CT The first menu item in the User Menu See User Menu on pag...

Page 51: ...in Run Mode The motor cannot be engaged and the gate cannot be moving ADJUSTING THE CLOSE TIMER The close timer assigns how many seconds will pass before the operator initiates automatic closure of a...

Page 52: ...on the date and time display press SELECT 8 To exit the User Menu press the MENU button A gate status appears in the display indicating you have returned to Run Mode NOTICE A date or time field must...

Page 53: ...pen or close command is ignored and LCD appears blank System remains in this disabled state until reset or battery recovers to 24V AP 2 AC LOSS AUTO OPEN Operator automatically opens gate five seconds...

Page 54: ...TIMER display appears 2 Press NEXT until the LCD CONTRAST display appears 3 Use the SELECT and NEXT buttons to navigate and change the number on the display 4 To exit the User Menu press the MENU but...

Page 55: ...atic close timer and causes its menu to disappear You must set HC to 1 to comply with UL 325 Type D protection Refer to Table Notes COM CLOSE HO 0 OFF Hold to Open 0 off 1 on SimilartoHOLDTOCLOSE butc...

Page 56: ...death FA 0 OFF Forced Open Alert 0 off 1 on Intended for highly secure facilities Set to 1 the operator sounds the 3 second warn before operate buzzer alarm and initiates a closure if the gate is forc...

Page 57: ...e on page 52 N A LD 5 LCD Contrast 5 0 through 9 Under some extreme high or low temperature conditions it may be necessary to adjust LCD contrast Display is adjustable from 0 9 with a factory default...

Page 58: ...ce numbered menu selections Table Note 1 For gate operators using Type D entrapment protection an automatic closing device such as a timer loop sensor or similar device shall not be employed Table Not...

Page 59: ...operator must be in Run Mode with a gate status showing on the display The motor cannot be engaged and the gate cannot be moving NOTICE The menu items Usage Class Gate Handing Gate Weight and Gate Le...

Page 60: ...operator model used at the site NOTE This menu item only appears if applicable when you set the OT operator type N A LL 0 OFF Learn Limit 0 Normal operation 1 Reset limits A setting of 1 places opera...

Page 61: ...motor and the gate opening speed increases as you go up the number scale A setting of 1 slows the gate travel to approximately 15 seconds A setting of 10 speeds up gate travel to approximately 10 sec...

Page 62: ...B B SG 0 OFF Sequenced Gate 0 solo operator 1 Loop View 1 2 Loop View 2 3 Loop View 3 4 Loop View 4 Establishes communication after wiring twoormoregateoperatorsassequential gates This SG menu item on...

Page 63: ...are See Note SS 0 OFF IES STOP ONLY 0 stop reverse for 2s 1 stop only In a Usage Class 4 environment operator can be set to stop gate and not reverse gate travel after an IES trip N A LC 0 0 0 SECS Le...

Page 64: ...Sensor Common Sensor Input EO 0 STOP ONLY EYE OPEN LOGIC 0 Open eye stops only 1 2s reverse to close Default setting is non reversal if open photo eye is triggered while opening A setting of 1 causes...

Page 65: ...res an NO output S e n s o r Common Sensor Input S1 0 Sensor 1 Type 0 disabled 1 NOT USED 2 EYE CLOSE 3 EDGE CLOSE 4 EYE OPEN 5 EDGE OPEN 6 EDGE BOTH 7 EYE BOTH UL 325 2018 sensor input setting for ex...

Page 66: ...tion of the Center Loop Shadow Loop when triggered Setting 1 prevents opening and closing of the gate when the Center Loop is tripped if the gate is on either opened or closed limit switches Setting 0...

Page 67: ...n electronic relay with capacity for switching a DC load only The User 2 Relay is limited to 48 Volts DC and 4A maximum load Up to 45 optional relay functions exist See Figure 68 Setting the User Rela...

Page 68: ...k 1 to 99 Network drop address Set system address for network communication 0 no network communication 1 99 sets individual polling addresses Use addresses 1 4 when connecting to HyNet RS 485 ELD0 RUN...

Page 69: ...Controller Display Connections CLD 0 RUN MODE CENTER LOOP SET 0 Run mode 1 Show frequency 2 Show call level 0 7 3 Set Frequency Controls Hy5A or Hy5B Center Loop Shadow detector If an Hy5B is used ad...

Page 70: ...aller Menu press the MENU button The gate status appears in the display indicating you have returned to Run Mode NOTICE Two options one for OPEN SPEED the other for CLOSE SPEED appear in the Installer...

Page 71: ...efault setting is 0 5 Use NEXT button to change number on display to 1 and then press SELECT 6 To exit Installer Menu press MENU button Gate status appears in display indicating you have returned to R...

Page 72: ...hreshold Over time degrading gate hardware and other site issues such as road settling or debris on the gate rail V track can occur As the gate hardware ages and becomes stiffer the SwingSmart motor c...

Page 73: ...ry default setting is 2 4 Use the SELECT and NEXT buttons to navigate and change the number on the display 5 To exit the Installer Menu press the MENU button The gate status appears in the display ind...

Page 74: ...a notebook or if you have a laptop computer you can use HySecurity s START software and download the menu settings and save them to a file to upload to the operator at a later date NOTICE When you pr...

Page 75: ...ions and its monitoring capabilities This section explains how to z Make connection on the Smart DC Controller z Integrate with Security Systems z Adapt User Relays for your Gate Site Figure 48 Smart...

Page 76: ...IN OBS LOOP OUTOBS LOOP CENTER LOOP SENSOR COM 24V EMERG OPEN SHOW LEDs COMMON TERMINALS HY 5B FREE EXIT HY 5B INSIDE LOOP HY 5B OUTSIDE LOOP HY 5B CENTER LOOP RS 485 COMMUNICATION USB PORT USER RELA...

Page 77: ...e of sight external stop button or 3 button station Open Open Normally Open N O input DO NOT use for radio or remote access controls Line of sight external open button or 3 button station Close Close...

Page 78: ...g loop Optional settings available Installer Menu item IR Outside Obstruction Loop Outside Obstruction Vehicle Detector N O input Inside reversing loop Optional settings available Installer Menu item...

Page 79: ...G OPEN overrides photo eye edge sensor commands Do not connect an external control to STOP or OPEN inputs unless controls are located in clear view of entire gate area Use RADIO OPEN input or RADIO OP...

Page 80: ...us updates and control commands are easily integrated with a central controller computer or server which becomes the primary master to the connected operators Several physical operators 1 to 99 can be...

Page 81: ...vehicle detectors are clear and no other open command is present Mode 2 The close timer does not wait for vehicle detectors to clear but instead it starts counting down as soon as the open limit is r...

Page 82: ...Controller z Very low power draw which is important for maximum UPS capability during a power failure and for solar applications z Cross talk between multiple loops is impossible z Best operating freq...

Page 83: ...x Type Vehicle Detectors on page 85 5 Repeat Steps 1 through 3 for each Hy5B detector 6 To enable the detectors turn on power The detectors will immediately tune if they are connected to loops Make su...

Page 84: ...ble Functions Display Meaning Installer Menu Setting Options Bold Default OR 1 Outside Obstruction loop detector function 0 Pause closing only 1 Enable reverse to full open IR 1 Inside Obstruction loo...

Page 85: ...Smart DC Controller 3 If multiple detectors are used route the power wires and common wire from socket to socket daisychaining rather than individually running each wire to the same location See Figur...

Page 86: ...put becomes active when an open limit is triggered and deactivates when open limit is released or a close command is received Use this output for a traffic light 4 Open limit pulse output Triggers a s...

Page 87: ...made in Installer Menu 14 Gate nearing full travel output Activated when gate is approaching full open or full closed Relay activates three feet from where software expects limit switch to be trigger...

Page 88: ...gSmart DC operator 32 Backoff Pulse Not functional in SwingSmart DC operator 33 Transient In Pulse Not functional in SwingSmart DC operator 34 Transient Out Pulse Not functional in SwingSmart DC opera...

Page 89: ...or without regard to preference z Be sure both operators are running the same software version The software version is available on the display by pressing the RESET button on the operator The softwar...

Page 90: ...Main power in 115 230VAC power conduit if required Conduit for Dual Gate wiring Conduit Conduit for Vehicle Detector wires may be shared with low voltage control wires PUBLIC SIDE SECURE SIDE SwingSm...

Page 91: ...B B Only ground to one unit Do NOT attach the shield wire to both units Shield wire to Ground EXIT LOOP BLOCK EXIT INOBS LOOP OUTOBS LOOP CENTER LOOP SENSOR1 SENSOR COM 24V EMERG OPEN SHOW LEDs A U S...

Page 92: ...ate operators will be in constant communication most often in a peer to peer relationship For example z Any control input that is attached to secondary NOTICE For proper operation you must set the oth...

Page 93: ...e used in connecting sequenced gates Refer to Wire Diagram Interlocked Pair of Operators using DUAL GATE Wiring on page 77 Be sure to connect the wires in pairs to the same terminal ports A A B B COM...

Page 94: ...an online member 4 Click to Download S T A R T software for Smart Touch and Smart DC 5 Read the End User License Agreement and if you agree to the terms click on I accept bottom of the page 6 Click R...

Page 95: ...utine maintenance is needed for the electrical system or controls If the environment is very sandy or dusty or has many insects be certain to seal all holes in the electrical enclosure Blow the dust o...

Page 96: ...ok for the following z Sweep debris out and away from the chassis z Verify drive belt has proper tension Check for drive belt wear Fraying edges or missing teeth indicate that drive belt needs to be r...

Page 97: ...is properly tensioned it should move about 1 16 to 1 8 inch 16 to 32 mm 5 To replace or re tension the drive belt Loosen the four motor bracket nuts and move the motor accordingly 6 With the belt prop...

Page 98: ...008 50Ah MX002013 The batteries supplied in the SwingSmart operator are state of the art AGM batteries Do NOT use flooded cell batteries as damage may occur to the unit Wear protective clothing while...

Page 99: ...and red terminals 3 As you slide the battery onto the tray connect the black wire to the black terminal on the right battery 4 Return the support tray to its original position and secure it properly...

Page 100: ...erminal is the same as the input terminal labeled RADIO OPEN along the left edge of the Smart DC Controller 6 Mount an external antenna onto the top of a fixed fence post near the operator 7 Connect t...

Page 101: ...VDC 24VDC 12VDC 12VDC A achthepowerwirefromthelock totheappropriatepowerspade ConnectCOMonboard toCOMonUSER1RELAY ConnecttheCOMwirefrom thelock ASolenoidlocka achestoNO AMagLocka achestoNC COM DUALGAT...

Page 102: ...ss and for Emergency Close z Installing in ground vehicle loops with the option to set the Close Timer CT in the Installer Menu INSTALLING VEHICLE DETECTORS AND LOOPS A vehicle detector passes a small...

Page 103: ...cable is used Never route high voltage circuits in PVC conduit near a loop 5 Loopandlead inwireshouldbeonecontinuous piece Avoid splices if possible If a splice is necessary for any reason pot the sp...

Page 104: ...and obstruction sensing logic only Because of their slower speeds closing logic is a poor choice for security gate systems Since there are several ways that the gate may be left standing open and bec...

Page 105: ...10 I2C BUS ERROR Hy5B vehicle detector Communications alert Alert indicates detector is not communicating properly with Smart DC Controller Alert occurs if detector is unplugged or connection is unst...

Page 106: ...ortion of the loop operational z INFINITE never drops the call The INFINITE setting requires a certain amount of signal strength A threshold is maintained and it will hold the call forever The loop co...

Page 107: ...uable because it provides information about how well the loop is actually seeing a specific vehicle For example it may be useful to check to see if the loop is easily detecting the middle of a high be...

Page 108: ...s replaced by an INSIDE OBSTRUCTION loop the FREE EXIT loop is replaced by an INSIDE OBSTRUCTION loop SECURE SIDE C D E F CENTER LOOP FREE EXIT or INSIDE OBSTRUCTION LOOP NOTE A minimum of three 3 det...

Page 109: ...e FREE EXIT loop is replaced by an INSIDE OBSTRUCTION loop SECURE SIDE C D E F CENTER LOOP FREE EXIT or INSIDE OBSTRUCTION LOOP NOTE A minimum of three 3 detectors are required for this type of gate D...

Page 110: ...able sensor inputs are available for use and must be programmed to a non zero number when initial configuration is performed The three inputs are labeled Sensor 1 Sensor 2 and Sensor 3 and are configu...

Page 111: ...l for monitoring and powering purposes The sensor becomes actively powered when the gate operator s motor runs CAUTION CAUTION CAUTION CAUTION Connect all contact and non contact sensors to same power...

Page 112: ...s recommended one photo eye to guard the open direction and the other for the close direction of travel unless gate edges for entrapment protection are installed z Three wires to the receiver and two...

Page 113: ...to 0 the next time the Close Limit Switch is triggered or the RESET key is pressed Notes about retro reflective systems Correct installation and alignment of a retro reflective photo eye and its refl...

Page 114: ...oller Installer Menu Functions on page 60 for more information REFERENCE INSTALLING GATE SENSORS ON SWING GATES Three sided sensors are ideal for swing gates If gate clearance is 4 inches 10 cm or mor...

Page 115: ...opens Additionally if communication between transmitterandreceiveriseverlostorcorrupted due to too much RF noise in area then the receiver will indicate to control board that the edge is tripped even...

Page 116: ...already in Safe Mode Operator will not function until it is reset which can occur by z An Open or Stop command from a push button control z Pressing black button on operator side z Pressing RESET butt...

Page 117: ...atteries are 90 depleted Gate will automatically open or close depending upon setting chosen No additional automatic function is possible but limited push button control is available to 18V Refer to c...

Page 118: ...pears if gate drifts three times in a five minute period Check track to make sure it is level ALERT 4 MOTOR OVERLOAD Thermal overload alert When alert is triggered gate can only fully open until alert...

Page 119: ...Loop CLD User Relay 22 Loop lead in wires and roadway should be checked for problems or replaced ALERT 8 LOOP SHORTED H y 5 B h a s d e t e c t e d a loopshorted to ground Caused by inadequate insulat...

Page 120: ...struction Loop OOLD or Center Loop CLD User Relay 22 Check traffic patterns at site Loop and lead in wires should be checked for problems or replaced ALERT 13 STIFF GATE S m a r t D C Controller has d...

Page 121: ...d to be replaced Batteries are not taking a charge properly Buzzer will chirp every minute until UPS batteries are replaced ALERT 19 FALSE SLOWDOWN Not used with DC operators Not used with DC operator...

Page 122: ...LERT 22 appears access Installer Menu Verify Installer Menu items DG Dual Gate and SG Sequential Gate are both set to zero ALERT 24 EXTERNAL RELAY FAULT Communication Lost with Hy8Relay module Appears...

Page 123: ...ected there is no load on operator Gate is non operational while this fault is triggered Possible causes z Motor wires disconnected z DC switch off z Linkage failure z Taper clamp being too loose 1 Ch...

Page 124: ...rectly See Primary and Secondary Wiring Connections z Primary Secondary not configured properly through Installer Menu z Operator not properly Operator not properly earth grounded z Primary Secondary...

Page 125: ...ire factory reset Corrupt software or data C a l l H y S e c u r i t y Technical Support for assistance ERROR 8 RPM SENSOR RPM sensor disconnected Motor Encoder or wires are damaged or unplugged Check...

Page 126: ...tor Failure to adjust and retest the gate operator properly can increase the risk of injury or death 4 V ri ez le fonctionnement de l ouvre barri re une fois par mois Le sens de la course DOIT s inver...

Page 127: ...les galets expos s 2 4 The operator is intended for installation only on gates used for vehicles Pedestrians must be supplied with a separate access opening The pedestrian access opening shall be desi...

Page 128: ...chement ou ces deux boutons doivent tre situ s dans le champ de visibilit de la barri re L activation des commandes de r enclenchement ne doit pas mettre en marche l ouvrebarri re 2 9 A minimum of two...

Page 129: ...mpeded by building structures natural landscaping or similar obstruction A wireless device shall function under the intended end use conditions c Un dispositif sans l comme un appareil qui transmet de...

Page 130: ...o instruc ons 2 subjected to negligence accident vandalism or damaged by severe weather wind ood re terrorism or war or 3 damaged through improper opera on maintenance storage or abnormal or extraordi...

Page 131: ...This page intentionally blank MX3640 01 Rev E 2020 SwingSmart DC Programming and Operations hysecurity com 800 321 9947 131...

Page 132: ...m shell cover ETL Listed UL 325 Usage Class I II III IV Cycle Tested 500 000 cycles Warranty 5 year 7 year single family residential w product registration The actual number of gate cycles available f...

Reviews: