19
22 - INSPECTION AND OPERATION
21.5 - Radio receiver connection (third party)
38 12V
39 OPEN
40 CLOSE
41 GND
The customer supplied radio receiver allows the gate operator to be operated
via remote, such as wireless key-card readers or user remote controls.
Connecting the Open (39) and Close (40) pins together with the relay of a
receiver enables step by step gate control. This configuration allows a single
button to control the gate in the following sequence:
Press - Gate Open
Press - Gate Stop
Press - Gate Close
Press - Gate Stop
Proper inspection of all equipment is required to ensure continuous
functionality, safety and to ensure reliable operation in all weather conditions.
Inspect electrical assemblies and wiring installations for damage, general
condition, and proper functioning to ensure the continued satisfactory
operation of the electrical system. Adjust, repair, overhaul, and test electrical
equipment and systems in accordance with the recommendations and
procedures in the gate operator system and/or component manufacturer’s
maintenance instructions.
Replace components of the electrical system that are damaged or defective
with identical parts, with manufacturer’s approved equipment, or its
equivalent to the original in operating characteristics, mechanical strength,
and environmental specifications. A partial list of suggested problems to look
for and checks to be performed are listed below:
22.1
Damaged, discolored, or overheated equipment, connections, wiring,
bearing caps and installations.
22.2
Excessive heat or discoloration at high current carrying connections.
(look for bluing or heat affected metal).
22.3
Misalignment of electrically driven equipment. (Causes strain on
pulley assemblies and bearings).
22.4
Poor electrical bonding (broken, disconnected or corroded bonding
strap) and grounding, including evidence of corrosion.
22.5
Dirty equipment and connections. Clean equipment and connections.
22.6
Improper, broken, inadequately supported equipment, wiring and
conduit, loose connections of terminals, and loose ferrules.
22.7
Poor mechanical or weld joints. Broken welds.
22.8
Condition of circuit breaker and fuses. Ensure that they are of the
correct type and amperage.
22.9
Insufficient clearance between exposed current carrying parts
and ground or poor insulation of exposed terminals. All exposed
connections must be covered (prevent arcing between exposed
parts, and electrical shock).
22.10
Broken or missing wire, connectors, etc.
22.11
Operational check of electrically operated equipment such as
motors, inverters, generators, batteries, lights, protective devices,
etc. Ensure proper functionality of all systems during inspections.
22.12
Ensure safety placards and warning signs are present as specified
within this document. Ensure proper functionality of all safety devices
as specified. Non-functioning or malfunctioning safety devices should
be replaced immediately.
Figure - RADIO RECEIVER
38
39
40
41
12V Power
Normally Open
Common
Ground
21.6 - Optional power output
10 GND
11 V+
When the control board is in standby mode, power is still present at terminals
10 and 11. If standby mode is to be used (especially in a solar application)
You may use the terminals 10 and 11 to provide power to accessories.
Please note that the output voltage of terminal 11 is the same as the highest
incoming voltage (on battery OR main power) to the control board.
For example:
If you are using a 12VDC battery to power to the control board connected to
the Battery input, and the voltage of the battery is 13.5VDC - terminal 11 will
have a 13.5VDC output.
If you are using a power supply input of 32VDC to the control board
connected to the Main Power input - terminal 11 will have a 32VDC output.
If you are using a power supply connected to Main Power (at 32VDC) and
also using a battery connected to the Battery input (at 13.5VDC) - terminal 11
will have an output of 32VDC.
7
8
9 10
11
Accessory
to be
powered
Summary of Contents for H12-ETL-1K
Page 2: ......
Page 27: ...27 1 1 2 2 A A B B COMPANY NICE APOLLO NAME CONTROL BOX GENERAL OVERVIEW 18 22 18 18 8 32...
Page 30: ...30...