Nice Apollo CBOX1K Manual Download Page 41

41

21 - EMERGENCY VEHICLE ACCESS 

22 - GLOSSARY 

21.1 

The automatic vehicular gate system must be designed to allow 

access to emergency vehicles under different operating conditions. 

21.2

  During normal powered operation, emergency vehicles access the 

gate by use of the emergency vehicle access device installed on your 

gate system. The type of device that is used in your community is 

dependent on your city codes. These devices may include (but are not 

limited to) Fire Department lock boxes, Click-2-Enter radio receivers, 

strobe light sensors, siren sensors, etc. 

21.3

  Check with your installer to determine if your gate system is equipped 

with a back-up power system. In the event of a primary (AC) power 

failure and a back-up system (DC) power failure (low charged or dead 

batteries for example), the system must have a release system to 

allow the gate to be manually operated. The release device must be 

accessible from either side of the gate and must be present so that 

emergency personnel can gain access through the gate under this 

condition. 

21.4

  If applicable, this system is equipped with a manual release system 

that will allow the gate to be pushed open in the event of a power 

outage or equipment failure. 

21.5

  NOTE: Never attempt to manually push open any gate with an 

operator attached to it until you have verified that power to the 

operator has been shut-off. 

21.6

  The automatic vehicular gate system must be designed to allow 

access to emergency vehicles under different operating conditions. 

21.7

  In the event of a power failure, the emergency vehicle access device 

may not be functional because the gate operator is not powered. 

NOTE: DC powered back-up systems are optional and your gate 

system may or may not be equipped with one. Check with your 

installer to determine if your gate system is equipped with a back-up 

power system. 

21.8

  For manual fail-safe gate operation, turn power to the operator OFF. 

If a backup power system is in use, be sure that this power is turned 

OFF also or disconnected. Once power is OFF, the gate can be 

manually operated, by disconnecting the gate attachment bracket 

(816).

LOCK- 

Ceases all operator function except HIGH PRIORITY inputs.

COMMERCIAL / GENERAL ACCESS VEHICULAR GATE OPERATOR- 

CLASS II -

 A vehicular gate operator (or system) intended for use in a 

commercial location or building such as a multi-family housing unit (five 

or more single family units), hotels, garages, retail store, or other building 

servicing the general public.

ENTRAPMENT - 

The condition when an object is caught or held in a 

position that increases the risk of injury.

FORCE STATIC - 

Constant load threshold for sensitivity setting.

FORCE DYNAMIC -

 Impact sensitivity setting.

GATE -

 A moving barrier such as a swinging, sliding, raising, lowering, or the 

like, barrier, that is a stand-alone passage barrier or is that portion of a wall 

or fence system that controls entrance and/or egress by persons or vehicles 

and completes the perimeter of a defined a ea.

(STEP H) HIGH PRIORITY - 

Step by step control.

INHERENT ENTRAPMENT SENSOR SYSTEM - 

An automatic sensor 

system which senses entrapment of a solid object and is incorporated as a 

permanent and integral part of the operator.

INDUSTRIAL / LIMITED ACCESS VEHICULAR GATE OPERATOR- 

CLASS III - 

A vehicular gate operator (or system) intended for use in an 

industrial location or building such as a factory or loading dock area or other 

locations not intended to service the general public.

RESTRICTED ACCESS VEHICULAR GATE OPERATOR-CLASS IV -

 A 

vehicular gate operator (or system) intended for use in a guarded industrial 

location or building such as an airport security area or other restricted 

access locations not servicing the general public, in which unauthorized 

access is prevented via supervision by security personnel.

RESIDENTIAL VEHICULAR GATE OPERATOR-CLASS I -

 A vehicular 

gate operator (or system) intended for use in a home of one-to four single 

family dwelling, or garage or parking area associated therewith.

STEP BY STEP - 

Command that opens-stops-closes-stops the gate with 

each press of the button.

SYSTEM -

 In the context of these requirements, a system refers to a group 

of interacting devices intended to perform a common function.

UNLOCK -

 Resumes normal operation after a blocked condition.

WIRED CONTROL -

 A control implemented in a form of fixed physical inter- 

connections between the control, the associated devices, and an operator 

to perform predetermined functions in response to input signals.

WIRELESS CONTROL -

 A control implemented in means other than 

fixed physical interconnections (such as radio waves or infrared beams) 

between the control, the associated devices, and an operator to perform 

predetermined functions in response to input signals.

Summary of Contents for CBOX1K

Page 1: ...Nice Apollo Control Box Vehicular Gate Operator Control Revision 1 0 0 0_6 2014 CBOX1K...

Page 2: ......

Page 3: ...ion 18 9 3 Push to open installation 19 9 4 Actuator mounting 19 9 5 Actuator wiring 20 9 6 Gate bracket mounting 20 9 7 Limit motor connection to the board 21 9 8 Limit switch adjustment 21 9 9 Setti...

Page 4: ...ction Dry contact inputs are provided for loop probe and photoelectric detectors as well as edge sensors guard station and fire department control of gate opening and closing Voltage outputs 12VDC and...

Page 5: ...he moving gate system No entry into the gate is ever authorized and should be prevented by whatever measures are required for that specific installation Care should always be used during installation...

Page 6: ...nal gate types 4 3 15 Any existing manual gate latches shall be removed or disabled when an automatic gate system is installed Use only mag locks controlled by the system 3 3 Gate system safety device...

Page 7: ...nt any device that operates the gate opener where the user can reach around over or through the gate to operate the controls Controls should be mounted at minimum 8 feet away from any moving part of t...

Page 8: ...ontrol board for STANDBY operation See section 16 for information on STANDBY mode Battery Connect wires to the battery terminal block The positive wire of the battery connects to the left terminal mar...

Page 9: ...included The CBOX1K control box is used for many different model operators The following pages show installation guides for these models Refer to the correct model operator section for instructions on...

Page 10: ...IDENTIFICATION Control Box 11111B T5 Actuator NT TO5012 T7 Actuator NT TO7012 Operator QTY QTY QTY QTY QTY QTY T5ETL 1K 1 1 1 1 0 1 T7ETL 1K 1 0 1 1 1 1 8 NT T51K NT T71K INSTALLATION NT T51K NT T71K...

Page 11: ...the rear pivot bracket using the T5 or T7 graph provided on the next pages The graphs serve to establish the dimensions A and B and the value of the maximum opening degree of the gate Important The va...

Page 12: ...5 16 6 11 16 7 1 16 7 1 2 7 7 8 8 1 4 8 11 16 9 1 16 9 7 16 9 13 16 10 1 4 10 5 8 11 7 16 11 3 15 16 4 5 16 4 3 4 5 1 8 5 1 2 11 13 16 12 3 16 12 5 8 13 13 3 8 Recommended installation line NOT RECOM...

Page 13: ...1 7 16 11 13 16 5 5 16 6 5 16 6 11 16 7 1 16 7 1 2 7 7 8 8 1 4 8 11 16 9 1 16 9 7 16 9 13 16 10 1 4 10 5 8 11 7 16 11 NOT RECOMMENDED VALUES AREA Recommended installation line C 4 1 2 3 1 2 5 1 8 6 6...

Page 14: ...of the T5 T7 to the attachment bracket using the supplied bolt and washer with a 13mm metric socket as shown Be careful not to over tighten the bolt 2 3 1 Unlock the strain relief bushing located on t...

Page 15: ...2 into the connection labeled Motor 2 Note Motor 1 Make sure motor lead connector is plugged in below the limit 5 pin terminal connector T5 and T7 Limit and Encoder wiring T5 and T7 Motor wiring green...

Page 16: ...e RED and BLACK motor leads Using the OPEN button on the front of the Control board hold the button down until the gate reaches the fully intended open position Adjust the Open Limit Switch until the...

Page 17: ...x 11111B 816 Actuator with 8 harness 816X Actuator with 38 harness Supplied with 16501K Pivot Arm 1116 2 with 16501K Gate attach bracket 10025215 2 with 16501K Bolt kit 2 with 16501K 9 15501K 16501K I...

Page 18: ...rate of speed of the gate it is critical that the measurements below are followed The pivot arm may need to be cut to achieve the correct placement of the actuator mounting hole Measurements are take...

Page 19: ...g hole Measurements are taken from the center of pivot of the gate hinge Vertical position of pivot arm DIRECTION OF OPENING GATES CLOSED HINGE POST HINGE POST LEFT HAND SWING RIGHT HAND SWING TOP VIE...

Page 20: ...n below These connections enable the Apollo 816 limit switch and smart sensor inputs into the gate controller 816 limit switch and smart sensor wiring Connect the Apollo 816 actuator cable to the 5 pi...

Page 21: ...pin connector for motor 1 into the connection labeled Motor 1 on the controller as shown For a dual gate installation install the 5 and 3 pin and connector for motor 2 into the connection labeled Mot...

Page 22: ...te limit wires CLOSE LIMIT Red CLOSE LED 3 Using the CLOSE button on the front of the Control Board hold the button down until the gate reaches the fully intended closed position 4 Adjust the Closed L...

Page 23: ...23 10 1 PARTS IDENTIFICATION Control Box CBOX1K Chassis CHBOX350 Arm Assembly ABOX350 10 35001K 36001K INSTALLATION 35001K 36001K INSTALLATION...

Page 24: ...istances are from the hinges square to the center of the mounting post Longer gates should operate at slower speeds E C B D A OPTIMUM SETTING SHOWN IN GREEN A Open Degrees B Inches C Inches D Inches E...

Page 25: ...the gate in the closed position and level for proper operation 3 Conduit should be considered at this time for cable routing from the control box to the chassis assembly Welding mounting bracket Weld...

Page 26: ...to the primary arm using a 1 2 x 2 1 4 hex bolt brass washers and lock nut The stop tab should be positioned away from the gate Install the aluminum adjustable arm to the secondary arm using the 1 2...

Page 27: ...te attach bracket to the gate Note Permanent welds or bolt attachment should be completed once limits are set Make sure that the primary arm is locked into the stop tab on the secondary arm Located in...

Page 28: ...wiring White Close limit Orange Open Limit Green Limit Common Green Orange White 1 2 3 4 5 3500 3600 Limit Wiring White Close limit Orange Open Limit Green Limit Common Green Orange White 1 2 3 3500...

Page 29: ...N limit switch is now set Note if red LED illuminates reverse orange and white limit wires CLOSE LIMIT Red CLOSE LED 3 Using the CLOSE button on the front of the Control Board hold the button down unt...

Page 30: ...irection MUST be set prior to learning the board 2 Press and hold the Open or Close button on the gate controller until the gate is 50 open 3 Press ENTER to allow the control board to scan for attache...

Page 31: ...ars hard shutdown GUARD STATION Guard Station Open 34 Dry contact input for a guard station open switch Momentarily shorting the digital input to GND opens the gate to the full open position with the...

Page 32: ...cting other assigned remote controls This procedure needs to be performed at the Nice Plug In Receiver with the affected Nice remote control 1 Press and hold the button on the side of the Nice receive...

Page 33: ...for the operator connection The wire table is based on stranded copper wire Wire run calculations are based on a 110 VAC power source with a 3 voltage drop on the power line plus an additional 10 red...

Page 34: ...g edge of the closing gate The EXIT sensor input is provided to activate to open the gate or re open a closing gate upon sensing an exiting vehicle Figure FIRE DEPT INPUT 15 2 Magnetic lock connection...

Page 35: ...ty equipment and connections Clean equipment and connections 16 6 Improper broken inadequately supported equipment wiring and conduit loose connections of terminals and loose ferrules 16 7 Poor mechan...

Page 36: ...lls Figure LAYOUT FOR IN GROUND LOOPS Entrapment Protection Inputs Typical Installation Diagram Utilizing Photocells Figure LAYOUT FOR PHOTOCELLS Loop Safety Loop Safety Loop Shadow Loop Exit 4 Min fr...

Page 37: ...at the control panel before making any electric service power connection Be aware of all moving parts and avoid close proximity to any pinch points Know how to operate the manual release Adjust the un...

Page 38: ...Stop gate movement Close the gate Figure GENERAL BOARD OVERVIEW THE PROGRAMMING BUTTONS INDICATED IN THE ABOVE REFERENCE SHOULD BE USED ONLY AFTER UNDERSTANDING THE MANUAL AND ITS RELATION TO THE PROG...

Page 39: ...itivity of sudden impact force to the moving gate on a scale of 1 to 10 1 being most sensitive ESC Exit the FORCE menu 20 2 Speed Max Sets the limit of maximum allowed gate speed on a scale of 20 to 1...

Page 40: ...dvance Settings The following settings are available for customizing the gate operator as required by the customer s installation requirements Set Language English Spanish French Set clock 12H 24H Set...

Page 41: ...perator or system intended for use in a commercial location or building such as a multi family housing unit five or more single family units hotels garages retail store or other building servicing the...

Page 42: ...Table 3 SYMPTOM S POSSIBLE SOLUTION Check that power to the circuit board is turned ON Check terminal block wiring for loose or broken wires If voltage measures OK check the terminal block Check the...

Page 43: ...43 1 1 2 2 A A B B COMPANY NICE APOLLO NAME CONTROL BOX GENERAL OVERVIEW 18 22 18 18 8 32...

Page 44: ...LE POLE 1115 1 4 SWITCH PUSH BUTTON CNTRL BOX 1119 1 5 1050 CIRCUIT BOARD 1050 1 6 1050 BOARD MOUNT KIT 10055090 1 7 NICE RECEIVER 318NPI 1 8 1 1 2 2 A A B B TITLE Company 2 6 8 3 7 4 5 1 Note Control...

Page 45: ...the information from the dated proof of purchase receipt to confirm the warranty period or the technician will confirm your extended warranty period through your registration information on file The t...

Page 46: ...e and has tested the gate to make sure that the gate stops and reverses a short distance with minimal resistance applied Approximately 40 lbs on a swing gate at the end of the gate 8 The installer has...

Page 47: ...47...

Page 48: ...Contact us Nice Group USA Inc 12625 Wetmore Road Suite 218 San Antonio TX 78247 Ph 1 210 545 2900 Fax 1 210 545 2915 www niceapollo com www facebook com NiceApollo...