10.2 - POST INSTALLATION
IMPORTANT
-
Never weld parts to the gate or posts when the operator circuit board is powered. Doing so may damage
the board beyond repair.
Post location guide
Determine the angle that the gate will open to (A). Select the coordinates (B&C) as shown on the chart below. Distances are
from the hinges square to the center of the mounting post. Longer gates should operate at slower speeds.
E
C
B
D
A
OPTIMUM SETTING SHOWN IN GREEN
A
Open Degrees
B
Inches
C
Inches
D
Inches
E
Inches
Approximate
seconds to
open
90
10
31.2
46.3
40.6
15
90
10
30
47.1
42
16
92
15
30
42.1
34
15
97
13.5
25.5
46.3
46.8
17
97
15
25
45
47.1
16
100
20
25
40
43.7
13
107
20
20
42.4
53.5
17
110
25
20
37.4
50.6
13
116
25
15
39.3
58.4
16
117
20
15
44.3
50.3
20
35001K & 36001K INST
ALLA
TION