Cable routing, AMS 10
Recommended cable routing from the connection box
to the condensation water hose connection to AMS 10.
There is a switch between the cold and hot sections of
the heating cable at the marking on the cable. The
marking may end up at the edge of the hole for the cable
grommet.
1. Pull off the protective paper and secure the gasket
to the condensation water connection, see image.
2. Thread hose clamp on.
3. Route the heating cable through the condensation
water pipe.
4. Route the heating cable through the drain pipe on
the connection plate, see image.
LE
K
1.
2.
3.
5. Pull the insulation down slightly, connect the hose
to the drain pipe and tighten the hose clamps, see
image.
LE
K
1.
2.
3.
6. Push the insulation up towards the trough and se-
cure it using cable ties, see image.
LE
K
1.
2.
3.
7. Stretch the heating cable and ensure that the
marking on the heating cable is as close to the drain
pipe as possible.
8. Install the connection plate on the right foot on AMS
10, seen from the rear. Use the mounting bolt that
the heat pump is secured with. (See image of relev-
ant AMS 10 model.)
AMS 10-8
L
E
K
AMS 10-12
L
E
K