List of components

For the Installer

27

FIGHTER 310P

 

   

Connection 

  Setting out  dimensions

 

 

 

  

C

  70  Supply line, heating system  .......................................................  Compression ring Ø  22 mm . 100  ....... 465 ........   90
  71  Return line, heating system  .......................................................  Compression ring Ø  22 mm . 130  ....... 465 .......  190
  73  Cold water connection  ...............................................................  Compression ring Ø  22 mm . 260  ....... 465 .......  290
  74  Hot water outlet from water heater  ............................................  Compression ring Ø  22 mm . 290  ....... 465 .......  345
  77  Side access panel, valve coupling
  78  Filter cover
  79  Drain and overflow water connection, water heater  ...................  R 15 male (with compression ring removed)
  80  Drain connection, heating system  .............................................  R 15 male
  82  Electrical supply for load monitor (accessories)
  84  Ventilation opening
  85  Expansion vessel
  86  Temperature sensor, evaporator
  87  Temperature sensor, extract air (concealed)
  88  Temperature sensor, immersion heater operation
  89  Temperature sensor, supply line
  90  Ventilation connection exhaust air  .............................................  Ø  125 mm  ......................... 2095  ....... 295 .......  160
  91  Ventilation connection extract air  ...............................................  Ø  125 mm  ......................... 2095  ....... 295 .......  485
  94  Temperature sensor, compressor operation
  95  Overflow pipe, safety valve water heater
  96  Overflow pipe, safety valve heating
  97  Condensation water outlet, fan box
  98  Overflow water discharge  ..........................................................  PVC-pipe Ø 32 mm (outside diameter)
  99  Collection funnel, waste water
 103  Serial number sign
105  Pressure reduction valve
106  Expansion vessel, tap water
107  Switch, “Fan speed”
108  Tundish from temperature relief valve
109  Tundish from pressure valve
115  Terminal block
116  Temperature limiter, compressor
118  Filling hose
145  Temperature and pressure valve

  1  Immersion heater 8 kW
  3  Operating thermostat, backup heating
  6  Temperature limiter, immersion heater
  7   MCB, circulation pump, 

 automatic heating control system and compressor

  8  Switch, positions 0 - 1 - 
  9  Terminal block, power supply
  10  Contactor step 1
  11  Terminal block, docking
  13  Terminal block
  14  Terminal block
  15  Outdoor sensor
  16  Circulation pump
  17  Air screw, circulation pump
  18  Pushbutton, “Extra hot water”
  19  Shunt motor with handwheel
  20  Connector, exhaust air fan
  25  Selector switch for operating mode
  26  Motor protection, compressor
  27  Compressor
  28  Operating capacitor, compressor 
  29  Relay card with power supply unit
  30  Indicator lamp, “Compressor”
  31  Indicator lamp, “Defrosting”
  32  Indicator lamp, “Immersion heater”
  33  High pressure pressostat
  34  Microprocessor card
  35  Capacity setting, circulation pump
  36  Fan, exhaust air
  37  Knob, “Heating curve selection”

  38  Knob, “Heating curve offset”
  39  Pushbutton, “Channel selection”
  40  Numerical display with control card behind
  41  Low pressure pressostat
  42  Pressure gauge, boiler
  43  Shunt valve
  44   Shutoff valve, pump and supply line heating system
  46  Filler valve, water heater
  47  Safety valve, water heater
  48  Expansion valve
  49  Filling valve, heating system
  50  Shutoff valve, return line heating system
  51  Drain valve, heating system
  52  Safety valve, heating system
  53  Vacuum valve (hidden)
  54  Fan transformer
  55  Indicator lamp, “Immersion heater”
  56  Indicator lamp “Circulation pump”
  57  Starter capacitor, exhaust air fan
  58  Strain relief, docking cable
  59  Strain relief, supply cable
  60  Fan module
  61   Docking connection, requires special pipe from NIBE
  62  Evaporator
  63  Air filter (Filter type G2)
  65  Drying filter with tank
  66  Type plate
  67  Contactor step 2
  68  Compressor heater

147  Filling hose
148  Pressure reduction valve
149  Connection for flexible hose to CW-side
150  Connection for flexible hose to heating-side
151  Filling valve, heating system (CW-side)
169  Temperature limiter, compressor

Summary of Contents for FIGHTER 310P

Page 1: ...INSTALLATION AND MAINTENANCE INSTRUCTION FIGHTER 310P 230V MOS GB 0850 4 FIGHTER 310P 511350 L E K Fighter 310P Fighter 310P...

Page 2: ...LEK LEK 1 2 LEK LEK 3 4 5...

Page 3: ...ve offset 0 20 Heating curve offset 2 20 Setting using diagrams 20 Dealing with malfunctions Low temperature or a lack of hot water 21 Low or a lack of ventilation 21 Low room temperature 21 High room...

Page 4: ...40 285 21 MARKARYD SWEDEN Maxiumum water supply pressure 16 bar Immersion heater R50 8000W 230 V Operating pressure tap water 6 bar Expansion vessel tap water charge pressure 3 5 bar Expansion vessel...

Page 5: ...o that its temperature drops and the refrigerant changes state from gas to liquid The refrigerant then goes via filters to the expansion valve where the pressure and temperature are further reduced Th...

Page 6: ...4 Upper visible part of the front panel Display screen Art nr 611603 2 1 bar 3 0 4 2 1 bar 3 0 4 2 1 bar 3 0 4 41 83 90 5 111 98 6 523 70 5 135 3 261 5 Switch Pressure gauge Indicator lamps Extra hot...

Page 7: ...e Dealing with malfunctions Indications on the numerical display NOTE When switching from Standby mode to normal mode 1 the numerical display can remain dimmed for a brief period This can also occur a...

Page 8: ...r hidden part of the front panel Art nr 611603 2 1 bar 3 0 4 2 1 bar 3 0 4 2 1 bar 3 0 4 111 98 6 523 Indicator lamps Heating curve selection Operating mode Channel selection I H J G L Miniature circu...

Page 9: ...ions G Art nr 611822 Operating mode When the heat pump is started all functions immersion heater circulation pump and auto matic heating control system are running Pressing the Operating mode button o...

Page 10: ...adjustment of basic settings Cold weather conditions If the room temperature is low increase the heating curve selection setting by one step If the room temperature is high reduce the heating curve se...

Page 11: ...wners LEK The heat pump and its ventilation ducting require some regular maintenance when the following points should be checked The numbers in brackets refer to the section Compo nent locations Clean...

Page 12: ...ion vessel normally 0 5 bar and 2 5 bar 25 mvp See Commissioning and adjusting Pressure gauge Extract air temperature Checking the safety valves L E K 2 1 bar 3 0 4 2 1 bar 3 0 4 FIGHTER 310P has thre...

Page 13: ...between about 50 and 60 C The Extra hot water knob 18 on the front panel is used to increase the hot water capacity Temperatures in FIGHTER 310P NOTE Thetransport guard around the compressor mustberem...

Page 14: ...es in the boiler section The pressure vessel in the FIGHTER 310P is approved for max 9 0 bar 0 9 MPa in the water heater and 2 5 bar 0 25 MPa in the double shell section Overflow water from the evapor...

Page 15: ...o building regulation approval notify the Local Authority of intention to install Warning to the installer Use only manufacturer s recommended replacement parts Tap water connection Hot and cold water...

Page 16: ...xhaust air devices it may be a good idea to install a silencer in the duct This is especially important if there are exhaust air devices in bedrooms Because the heat pump contains a flammable refriger...

Page 17: ...front panel see under Service Open ing the front panel and moving certain cables as described under Electrical diagram Changing the output Connection Power rating as set at the factory Max current NO...

Page 18: ...in defrosting mode In addition the flow temperature is limited to maxi mum 60 C Art nr 611 1 2 3 4 5 6 1 2 3 4 5 6 1 1 2 3 4 5 6 1 2 3 4 5 6 Immersion heater operation connec tion on delivery Limited...

Page 19: ...V SKYDDSKLENSP NNING SELV B 1 2 3 4 5 6 7 8 B R R A B RUMSGIVARE RUNDSTYRNING UTEGIVARE B A Rundstyrning eller effektvakt 14 Rundstyrning RS och effektvakt EV Brytande kontaktfunktion RS EV EV RS SKYD...

Page 20: ...ter screw to A Set the dimensioned capacity 35 on the circula tion pump 16 See the section Pipe connections Pump and pressure drop diagram Make sure that the switch is not in an intermediate position...

Page 21: ...heating control system and Front panel The heating water can be drained off through drain valve 51 using an R15 1 2 hose coupling Remove the cover 80 from the valve Now screw on the hose coupling and...

Page 22: ...2 V RMEKURVA 30 40 50 60 70 C FRAMLEDNINGSTEMPERATUR 40 C UTETEMPERATUR 10 0 10 20 30 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1514 13 12 11 10 8 7 6 5 4 3 2 1 40 C UTETEMPERATUR 10 0 10 5 5 30 40 50 60 7...

Page 23: ...witch 8 set to 0 MCB 7 tripped See the section Dealing with mal functions Resetting the miniature circuit break ers Tripped temperature limiter 6 Contact service Closed or throttled filler valve 46 on...

Page 24: ...the fault code must be cleared from the display by switch ing the heat pump off and on again Middle lamp lit Defrosting When there is too much ice on the evaporator defrost ing takes place After this...

Page 25: ...ault in the refrigerant circuit or its controller Request a service When the compressor is not operational the extract air temperature lies at about the same level as the room temperature High extract...

Page 26: ...ide temperature Actual value 04 Evaporation temperature Actual value 05 Extract air temperature Actual value 06 Curve slope Heating curve selection 07 Offset Heating curve offset 08 Temperature compre...

Page 27: ...ge 0 27 26 28 15 14 5 13 41 40 39 38 37 36 35 Re 1 Re 2 Re 3 Re 4 Re 5 Re 6 Re 7 29 230 V 12 V B1 C1 34 Brun Bl Svart VR1 C2 C3 F3 F1 F2 C4 L2 L1 5 2 1 3 4 P3 P1 P2 1 2 3 4 5 6 7 8 6 0 kW 1 Noll bleck...

Page 28: ...31 32 94 1 88 86 30 37 Fram ledning radiatorer 11 9 59 16 17 44 70 19 44 89 78 27 36 33 58 95 52 96 97 8 62 48 63 87 65 99 14 82 ter ledning radiatorer k v v v 41 103 51 80 71 50 66 151 149 74 73 84 9...

Page 29: ...atic heating control system and compressor 8 Switch positions 0 1 9 Terminal block power supply 10 Contactor step 1 11 Terminal block docking 13 Terminal block 14 Terminal block 15 Outdoor sensor 16 C...

Page 30: ...d in front of the heat pump for servicing Measuring principle Kl mring Klemmring Cu r r Kupferrohr A B och Undvik r rdragning inom streckmarkerat omr de f r att underl tta service Skyddsklensp nning 1...

Page 31: ...r Max pressure in double jacket volume 0 25 MPa 2 5 bar Breaking value high pressure pressostat 2 45 MPa 24 5 bar Breaking value low pressure pressostat 0 15 MPa 1 5 bar Design pressure in double jack...

Page 32: ...cabinet 385 535 mm Part no 089 428 ROOM SENSOR RG 10 In some cases a room sensor can be used as a sup plement to the ordinary automatic control system LEK 2 1 3 4 5 6 7 8 9 Accessories LEK Heightening...

Page 33: ...31 FIGHTER 310P...

Page 34: ...FIGHTER 310P 32...

Page 35: ......

Page 36: ...Tel 97 17 20 33 Fax 97 17 29 33 E mail info volundvt dk www volundvt dk NIBE Systemtechnik GmbH Am Reiherpfahl 3 29223 Celle Tel 05141 7546 0 Fax 05141 7546 99 E mail info nibe de www nibe de CH NIBE...

Reviews: