When the switch is set to “
” the compressor and
electronic controls of the
heat pump are off.
The fan is operational and the immersion heater is
controlled by a separate thermostat.
The numerical display is off. The automatic heating
control system is not operational, so manual shunt
operation is required. This is done by turning the
adjuster screw to manual mode and then turning the
shunt lever to the required position.
The display can remain unlit when returning to normal
mode. This is due to the boiler temperature being
above the heat pump's normal working area. The dis-
play comes on when the boiler temperature drops
once again to normal.
Dealing with malfunctions
21
For the Installer
FIGHTER 310P
Power switch position “ ”
If the operating disturbance cannot be rectified by means of the above an installation
engineer should be called.
If necessary set the switch to “
” (manual shunt operation necessary).
■
Automatic heating control system settings
not correct.
High room temperature
Should abnormal noise come from the fan, this may
need cleaning. Contact your installer.
Cleaning the fan
NOTE!
The hot water capacity can be increased for
24 hours by pressing in button (18).
■
Large amounts of hot water were used.
■
Switch (25) not correctly set.
■
Circuit or main MCB tripped.
■
Possible earth circuit-breaker tripped.
■
Switch (8) set to “
0
”.
■
MCB (7) tripped. See the section “Dealing with mal-
functions” “Resetting the miniature circuit break-
ers”.
■
Tripped temperature limiter (6). (Contact service)
■
Closed or throttled filler valve (46) on the water
h
e
a
t
e
r
.
Low temperature or a lack of
hot water
■
Circuit or main MCB tripped.
■
Possible earth circuit-breaker tripped.
■
MCB (7) tripped. See the section “Dealing with mal-
functions” “Resetting the miniature circuit break-
ers”.
■
Tripped temperature limiter (6). (Contact service)
■
Automatic control system settings not correct (40) .
■
Circulation pump (16) stopped. See the section
“Dealing with malfunctions” “Starting the pump”.
■
Air in boiler or system.
■
Closed valve (44) and (50) in the radiator circuit.
■
Initial pressure in expansion vessel too low. This is
indicated by low pressure on the pressure gauge
(42). Contact the installer.
■
Defrost mode, lamp (31) constantly lit; see “Indica-
tions on the numerical display”.
■
Filter (63) clogged (possibly replace).
■
Exhaust air device blocked or throttled down too
much.
■
Circuit or main MCB tripped.
■
Possible earth circuit-breaker tripped.
■
MCB (7) tripped. See the section “Dealing with mal-
functions” “Resetting the miniature circuit break-
ers”.
Low room temperature
Low or a lack of ventilation
In the event of malfunction or operating disturbances first
check the points below:
NOTE!
When returning to normal mode, do
not forget to reset the shunt lever to
the original position by turning the
adjuster screw to “A”.
LEK
Art.nr. 611822
2
1
bar
3
0
4
2
1
bar
3
0
4
2
1
bar
3
0
4
Transparent, blåfärgad film (ej hål).
67,5
57.25
26,3
86,3
92,7
126,8
129,8
132,8
145,2
336
41
19,2
83
90.5
111
98,6
523
10,5
Ø 52,8
53,5
135,3
130,7
15
70,5
135,3
r=4,5
37
23
9
2 st Ø 4,5, transparent, ofärgad film (ej hål).
OBS! Endast halv cirkel (radie=11)
Slits på baksidan
De 8 grårastrerade ytorna (Ø22)
skall ej förses med häftämne.
49,5
84,4
85,7
186,3
196,8
42,5
52
161
Ø 13
Ø 18,5
Hål 16 x 31
Hål 16 x 16
313,2
k.v.
v.v.
LEK
k.v.
v.v.
2
1
bar
3
0
4
LEK
15
12
24
21
6
18
R
3
9
15
ON
OF F
Adjuster screw
LEK
LEK
LEK
Summary of Contents for FIGHTER 310P
Page 2: ...LEK LEK 1 2 LEK LEK 3 4 5...
Page 33: ...31 FIGHTER 310P...
Page 34: ...FIGHTER 310P 32...
Page 35: ......