Control
29
For the Installer
FIGHTER 1220
Hot water temperature
Menu 1.12 Return
Pressing the enter button returns you to menu 1.0
R e t u r n
1 . 1 2
Menu 1.11.6 Return
Pressing the enter button returns you to menu 1.11.0
R e t u r n
1 . 1 1 . 6
Menu 1.11.2 Diff. Pool/min-temp
The difference from the value in menu 1.11.1 when
pool heating starts is stated here.
The value is adjustable between 0.5 and 3°C.
2 . 2 ° C
D i f f . P o o l / m i n - t e m p
1 . 1 1 . 2
Menu 1.11.3 Pool Time
The maximum time that pool heating can run is stated
here. The value is adjustable between 5 and 60 min-
utes.
2 0 m i n
P o o l T i m e
1 . 1 1 . 3
Menu 1.11.4 Pool pause
The time between pool heating is set here.
The value is adjustable between 5 and 60 minutes.
1 0 m i n
P o o l p a u s e
1 . 1 1 . 4
U
U
U
Menu 1.11.5 Sensor type
No function.
S e n s o r t y p e
1 . 1 1 . 5
U
Menu 2.4 Flow Temp./MAX
The set maximum level for the flow temperature to the
heating system is shown here. The value is adjustable
between 10 and 65 °C
The calculated flow temperature never exceeds the
set level irrespective of the outdoor temperature,
curve slope or offset heating curve.
Menu 2.1 Curve coefficient
The selected curve slope (heating curve) is shown
here. The Own curve function is activated at value 0,
see menu 2.6.0. The value can be set between curve
0 and 15.
Menu 2.2 Offset heating curve
The selected offset heating curve is shown here. The
value is adjustable between -10 and +10. NOTE! The
value is changed using the Offset heating curve knob.
Menu 2.3 Flow Temp./MIN
The set minimum level for the flow temperature to the
heating system is shown here. The value is adjustable
between 10 and 65.
The calculated flow temperature never drops below
the set level irrespective of the outdoor temperature,
curve slope or offset heating curve.
3 5 . 5 ( 5 5 ) ° C
F l o w T e m p . / M A X
2 . 4
5
C u r v e c o e f f i c i e n t
2 . 1
- 1
O f f s e t h e a t i n g c u r v e
2 . 2
3 5 . 5 ( 1 5 ) ° C
F l o w T e m p . / M I N
2 . 3
U
U
N
N
Flow temperature
Summary of Contents for FIGHTER 1220
Page 2: ......
Page 52: ...Wiring diagram 3 x 400 V N FIGHTER 1220 For the Installer 50 Sheet 3 4 Brine pump Relay board...
Page 57: ...55 For the Installer FIGHTER 1220...
Page 58: ...FIGHTER 1220 For the Installer 56...
Page 59: ......