Control
33
For the Installer
FIGHTER 1220
Menu 7.3.10 Return
Pressing the enter button returns you to menu 7.3.0
R e t u r n
7 . 3 . 1 0
Clock
Menu 7.4.0 Temp set back time 2
Settings, e.g. for night reduction can be selected in the
submenus to this menu.
T e m p s e t b a c k t i m e 2
7 . 4 . 0
Menu 7.4.1 Heating sys per. 2
The shunt system to be affected by day change period
2 is selected here. When shunt group 2 is installed
both Shunt 1 and 2 can be selected.
H e a t i n g s y s p e r . 2
7 . 4 . 1
Menu 7.4.2 Set back temp. +/-
Changes to the flow temperature with a day change,
e.g. night reduction are set here. The value is
adjustable between -10 and 10.
0
S e t b a c k t e m p . + / -
7 . 4 . 2
Menu 7.4.10 Return
Pressing the enter button returns you to menu 7.4.0
R e t u r n
7 . 4 . 1 0
U
U
Menu 7.4.3 — 7.4.9 Set Time Monday — Sunday
The time for the day change, e.g. night reduction, is
chosen here.
S e t T i m e M o n d a y
7 . 4 . 3
U
U
Menu 7.5.0 Timer XHW
Settings are made in the submenus of this menu when
extra hot water is required on a specific day.
T i m e r X H W
7 . 5 . 0
Menu 7.5.2 — 7.5.8 Extra HW Monday — Sunday
Here you select the period for respective days when
extra hot water should be activated. Hours and min-
utes for both start and stop are shown Equal values or
the stop time before the start time means that extra
hot water is not activated.
0 3 : 3 0 – 0 6 : 1 5
E x t r a H W M o n d a y
7 . 5 . 2
Menu 7.5.9 Return
Pressing the enter button returns you to menu 7.4.0
R e t u r n
7 . 5 . 9
Menu 7.8 Return
Pressing the Enter button returns you to menu 7.0.
R e t u r n
7 . 8
U
U
Menu 7.5.1 Timer Extra HW
You choose here whether the time setting should be
On or Off.
O f f
T i m e r E x t r a H W
7 . 5 . 1
U
Menu 7.7 Reset timers
You can chose here to reset the time settings. Auto-
matic return to Off after one minute.
O f f
R e s e t t i m e r s
7 . 7
U
Summary of Contents for FIGHTER 1220
Page 2: ......
Page 52: ...Wiring diagram 3 x 400 V N FIGHTER 1220 For the Installer 50 Sheet 3 4 Brine pump Relay board...
Page 57: ...55 For the Installer FIGHTER 1220...
Page 58: ...FIGHTER 1220 For the Installer 56...
Page 59: ......