System diagram
NOTE
This is the outline diagram. Actual installations
must be planned according to applicable
standards.
SYMBOL KEY
Meaning
Symbol
Shut-off valve
Non-return valve
Mixing valve
Circulation pump
Expansion vessel
Pressure gauge
P
Safety valve
Temperature sensor
Trim valve
Reversing valve/shunt
Heat pump
Radiator system
Domestic hot water
Hot water circulation
Designations according to standard EN 81346-2.
OUTLINE DIAGRAM
ELK 213
P
As a freestanding electric boiler
ELK 213
P
Installation alternative
ACCUMULATOR TANK (SP 300)
For installing ELK 213 to SP 300 accessory "Thread
flange kit" is required (Part no. 022 077).
In the event of large hot water demands, ELK 213, in-
stalled on double-jacket accumulator tank type, can be
used to heat the domestic hot water. This is also a good
solution for aggressive or hard water.
Recommended thermostat setting: 75 °C
ELK 213
BOILER WITH INTERNAL WATER HEATER
With the immersion heater installed on an existing boiler,
the existing control equipment is used.
Install the electric heater so that external heating does
not cause overheating, for example, in front of the fire-
box door (to prevent flames blowing out) or next to the
flue pipe (to prevent damaging heat radiation). A suitable
location is normally at the side of the boiler, directly on
the double jacketed heater’s flanges or similar location.
When the electric heater is installed on the existing
wood boiler and is solely responsible for the heating
demand, the flue should be sealed.
P
9
Chapter 3 | Pipe connections
NIBE ELK 213