F1345
Terminal blocks X1 and X8 in ELK 213 connect to the
terminal blocks X2-X4 in the heat pump as illustrated.
X2
X3
X4
L2 L3
N2 L1
N1
PE
1
2
3
4
5
6
1
2
3
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
N
X8
X1
X2
X4
X3
Värmepump
ELK 213
ELK 213
Heat pump
SMO S40
For connecting ELK 213 to SMO S40.
Terminal blocks X1 and X8 in ELK 213 connect to termin-
al blocks AA100-X3 and AA100-X8 in SMO S40 as illus-
trated.
Terminal block AA100-X4 connect to terminal block
AA100-X8 as illustrated.
L2 L3
N2 L1
N1
PE
1
2
3
4
5
6
7
8
9
N
1
2
3
C
X8
X1
Styrmodul
ELK 213
L
L
L
L
N
N
N
N
N
N
N
AA100-X3
AA100-X4
AA100-X8
ELK 213
Control module
SMO 20 and SMO 40
For connecting ELK 213 to SMO 20 and SMO 40.
Terminal blocks X1 and X8 in ELK 213 connect to termin-
al blocks X1 and AA7-X2 in SMO 20 and SMO 40 as il-
lustrated.
L2 L3
N2 L1
N1
PE
1
0 PE 2
3
4
1
2
3
4
5
6
7
8
9
N
X8
X1
X1
Styrmodul
ELK 213
AA7:X2
1
2
3
4
5
6
Control
module
ELK 213
S1155, S1255,
VVM S320, VVM S325
For connecting ELK 213 via accessory board AXC 40.
Terminal blocks X1 and X8 in ELK 213 connect to termin-
al block AA5-X9 in AXC 40 as illustrated.
L2 L3
N2 L1
N1
PE
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
9
N
X8
X1
Tillbehörskort
ELK 213
AA5-X9
Accessory card
ELK 213
11
Chapter 4 | Electrical connection
NIBE ELK 213
Summary of Contents for ELK 213
Page 1: ...IHB EN 2036 8 031403 INSTALLER MANUAL ELECTRIC HEATER Immersion heater NIBE ELK 213 LEK...