Time relay
ELK 213 is equipped with a time relay (KF1), which
blocks part of the immersion heater via contactor (QA2)
so that a maximum of 6 kW is connected during the first
two hours after ELK 213 has been disconnected.
LEK
LEK
Sensors
LEK
FQ10-BT8
BT35
1.
Install the thermostat bulb BT35.
2.
Install the temperature limiter bulb FQ10-BT8.
Connection of the
circulation pump
(GP10)
Connect the cable for any circulation pump fitted to
terminal block (X8), fused with miniature circuit breaker
(FC1) on 10 A and routed through separate strain-relief.
N
9
8
X8
GP10
L
PE