www.nibe.com
6
DVC 10-50 (W)
DESIGN AND FUNCTIONING
The ventilator consists of an indoor assembly unit with a decorative front panel, a cartridge, an air duct with a sound absorbing material and an outer
ventilation hood.
Cartridge is the basic functioning part of the unit.
It consists of a fan, a regenerator and two filters that ensure primary air filtration and prevent ingress of dust and foreign objects into the regenerator
and the fan.
The air shutters in the indoor unit close during the unit standstill and prevent back air drafting.
The ventilation hood to be installed on the outer wall prevents ingress of water and foreign objects into the unit.
Front part of the indoor unit
For decoration purpose and closing
of the air duct during the ventilator standstill.
Back part of the indoor unit
Consists of the control board and basic controls
on the side wall of the indoor unit.
Sound absorbing material
Prevents ingress of outer noise into the room.
Outer ventilation hood
Prevents ingress of water and foreign
objects into the unit. Each ventilator model
has a matching outer hood model.
Air duct
Plastic air duct.
Cartridge
It is an built-up structure consisting of a fan,
a regenerator and filters. It is designed for air flow
generation, energy regeneration and air filtration.
VENTILATOR DESIGN
Filters
Designed for filtration of the air stream
of dust and foreign objects and prevention
of the regenerator contamination.
Fan
Designed for air flow generation.
Regenerator
Designed for extract air energy
regeneration for warming up of supply air flow.
Cartridge is a solid block and cannot be dismantled.
NIBE DVC 10 has a cartridge with removable filters. They are removed for maintenance needs.
A socket connector to be connected to the control board in the back part of the indoor unit is routed from the cartridge.
CARTRIDGE DESIGN