VENTILATOR OPERATION WITH THE MOBILE APPLICATION FOR DVC 10-50W(L)
To enable operation of the unit with a mobile device install the
NIBE DVC 10
application to your mobile device. The application is available for download
at
App Store
,
Google Play
or via the QR code at the bottom of the page.
You mobile device must have the operation system matching the following parameters:
•
Version 7 or later for iOS. Compatible with iPhone, iPad, iPod.
•
Version 4 or later for Android.
After installation of the application turn the unit on and connect your mobile device to a wireless access point. Start the application for operation of the
unit at your mobile device. Detailed description of the connection to Wi-Fi read at page 21, 24.
Download application at
App Store
Download application at
Google Play
Turn unit on/off.
Selection of pre-set speed. Low, medium, high speed respectfully.
Manual speed setup. To activate the scroll bar check it.
Ventilation mode.
The ventilator operates in the supply or extract mode with a set speed. The fan rotation
direction depends on PC setting (extract mode by default).
Regeneration mode.
The fan rotation direction changes every 70 seconds. This mode enables heat recovery.
Supply mode.
The ventilator operates exclusively in the supply mode.
Night mode:
low speed timer activation for set speed, by default for 8 hours. The timer setting
is set during setup of the ventilator via a PC or the mobile application.
Party mode:
high speed timer activation, by default for 4 hours. The timer setting is set during
unit setup via a PC or the mobile application.
Current type of connection to the ventilator.
Home connection or connection via a cloud server through Internet respectively.
Wi-Fi connection indicator.
High speed activation indicator. It goes on after activation of any sensor.
This mode has higher priority as compared to the Party timer or Night timer mode.
When this mode is activated, all the other modes are deactivated. Upon elapse of the turn-off delay timer countdown (from 0 up to
24 hours, factory setting 30 minutes) the ventilator reverts to the previous mode. Press Power to deactivate this operation mode.
Humidity indicator. It glows if the indoor humidity is above the set point.
Indicator of external relay sensor. It glows if the external relay sensor is activated.
Indicator of external analogue sensor 0-10 V. It glows if a set value of the external sensor is exceeded.
Emergency shutdown indicator. It glows in emergency case.
Indicator button for resetting the filter timer. It glows after 90 days of non-stop operation of the unit. Pressing the button will reset the filter
timer of the Master unit only. All the units are equipped with a filter timer that has a nonvolatile medium. To reset the filter timer of the Slave
units set the DIP switch 3 to a respective position or use a downloaded program at your PC.
Summary of Contents for DVC 10-50
Page 33: ...www nibe com 33 NOTES...
Page 34: ...www nibe com 34 DVC 10 50 W NOTES...
Page 35: ...www nibe com 35 NOTES...
Page 36: ...NIBE155EN 01...